Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PISTON & RUDDER SERVICE INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PISTON & RUDDER SERVICE INC in 1000 S. NORDIC DRIVE, PETERSBURG, AK 99833 (NAICS 336612). OSHA activity number 340785641.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Piston & Rudder Service INC — free Get an email when a new federal OSHA severe-injury report for Piston & Rudder Service INC is published. One employer, no account, unsubscribe in one click.
Site address
1000 S. NORDIC DRIVE
City
PETERSBURG
State
AK
ZIP
99833
Mailing
PO BOX 1308, PETERSBURG, AK 99833
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
13
Ownership type
A

5 citations on file for this inspection.

1910.303 B07 IV

Serious Gravity 1 2 instances 3 exposed
Issued
Jul 29, 2015
Abate by
Aug 26, 2015
Penalty
Initial $1,200 · Current $384 Reduced
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.  Machine and aluminum shops, on or about 15 July 2015 and times prior thereto; two instances were noted where energized electrical outlets were damaged:       a. Machine shop, northeast corner; an electrical outlet had damage on the top receptacle.        b. Aluminum shop, south wall; an electrical outlet had damage on the lower receptacle.   This condition exposed employees to an electrical shock and burn hazards.
Recent events (2)
  • — I (S) $384
  • — Z (S) $1200

1910.304 A02

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 29, 2015
Abate by
Aug 26, 2015
Penalty
Initial $2,800 · Current $896 Reduced
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity.  Yard shop; on or about 15 July 2015 and times prior thereto; a Magic Chef refrigerator make and model unknown was plugged into an energized electrical outlet that was wired with reverse polarity. This condition exposed employees to electrical shock and burn hazards.
Recent events (2)
  • — I (S) $896
  • — Z (S) $2800

1910.305 B01 II

Serious Gravity 5 4 instances 13 exposed
Issued
Jul 29, 2015
Abate by
Aug 26, 2015
Penalty
Initial $1,600 · Current $512 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  Various facilities; on or about 15 July 2015 and times prior thereto; four instances were noted where electrical openings were not effectively closed:       a. Machine shop adjacent to milling machine; knockout plugs were missing on the bottom left and upper right hand sides on an energized outlet.       b. Machine shop adjacent to bay roll-up door; a knockout plug was missing from the upper right hand side of an energized outlet.       c. Counter area, adjacent to main entrance; a knockout plug was missing on the center plug on the right hand side of an energized outlet.         d. Building 916B, wood shop area; and energized electrical panel was missing a blank in breaker position number 1  This condition exposed employees to electrical shock and electrical burn hazards.
Recent events (2)
  • — I (S) $512
  • — Z (S) $1600

1915.134 B

Repeat Gravity 1 1 instance 3 exposed
Issued
Jul 29, 2015
Abate by
Aug 26, 2015
Penalty
Initial $2,400 · Current $768 Reduced
29 CFR 1915.134(b): Work rests were not kept a distance not to exceed 1/8 inch from the surface of the wheel.  Yard shop; on or about 15 July 2015 and times prior thereto; the work rest on a Baldor bench grinder, serial number 1184, was not properly adjusted to a maximum of 1/8 of an inch from the abrasive wheel. The gap between the abrasive wheel and work rest measured 1/4 of an inch. This condition exposed employees to a caught in hazard.     Piston and Rudder, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1915.134(b), which was contained in OSHA inspection number 419043, citation number 1, item number 4 and was affirmed as a final order on 11 July 2012, with respect to a workplace located at the Machine/fabrication shop.
Recent events (2)
  • — I (R) $768
  • — Z (R) $2400

1915.72 A01

Other-than-serious 1 instance 3 exposed
Issued
Jul 29, 2015
Abate by
Aug 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1915.72(a)(1): When ladders with broken or missing rungs or steps, broken or split side rails, or other faulty or defective construction were discovered, they were not immediately withdrawn from service.  Yard area; on or about 15 July 2015 and times prior thereto; the employer failed to remove damaged six foot wooden ladder from service. Ladder had a damaged rear rail. This condition exposed employees to a fall hazard.
Recent events (1)
  • — Z (O) $0

View Piston & Rudder Service INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340785641.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.