Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCAVOY DEVELOPMENT, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MCAVOY DEVELOPMENT, LLC. in 1226 LOUDON ROAD BUILDING 17-23, LATHAM, NY 12110 (NAICS 238160). OSHA activity number 340846955.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcavoy Development, LLC. — free Get an email when a new federal OSHA severe-injury report for Mcavoy Development, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1226 LOUDON ROAD BUILDING 17-23
City
LATHAM
State
NY
ZIP
12110
Mailing
2330 16TH STREET, TROY, NY 12180
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 19, 2015
Penalty
Initial $2,200 · Current $500 Reduced
29 CFR 1926.451(e)(1):  When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:     (a) Front of the building, upper roof, On or about August 13, 2015 - the ladder jack scaffold system was not equipped with a separate access ladder.  Scaffold deck to the ground elevation was approximately 18 feet, 3 inches.    (b) Front of the building, lower roof, on or about August 13, 2015 - the ladder jack scaffold system was not equipped with a separate access ladder.  Scaffold deck to the ground elevation was approximately 8 feet, 9 inches.
Recent events (3)
  • — J (S) $500
  • — C (S) $2200
  • — Z (S) $2200

1926.502 D16 III

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 19, 2015
Penalty
Initial $2,200 · Current $500 Reduced
29 CFR 1926.502(d)(16)(iii):  Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:    (a) Front of the building, On or about August 13, 2015 - the employee that was installing roof shingles and brackets was attached to a vertical lifeline rope grab system that had considerable slack, creating a fall hazard that would exceed 6 feet.
Recent events (3)
  • — J (S) $500
  • — C (S) $2200
  • — Z (S) $2200

1926.451 G01 I

Repeat Gravity 5 1 instance 1 exposed
Issued
Aug 19, 2015
Penalty
Initial $11,000 · Current $1,000 Reduced
29 CFR 1926.451(g)(1)(i):  Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:    (a) Front of the building, On or about August 13, 2015 - no fall protection was being used for the employee that was installing roof shingles and brackets, working from a ladder jack scaffold system.  Scaffold deck to ground elevation was approximately 18 feet, 3 inches.    McAvoy Development , LLC., was previously cited for a repeat violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.451(g)(1)(I), which was contained in OSHA inspection number 967349, citation number 2, item number 1, and was affirmed as a final order on January 14, 2015, with respect to a workplace located at 356 Westwoods Court, Schenectady, NY 12303.    McAvoy Development , LLC., was previously cited for a repeat violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.451(g)(1)(I), which was contained in OSHA inspection number 952009, citation number 1, item number 1c, and was affirmed as a final order on March 7, 2014, with respect to a workplace located at 33/14 Widgeon Way, Waterford, NY 12188.
Recent events (3)
  • — J (R) $1000
  • — C (R) $11000
  • — Z (R) $11000

View Mcavoy Development, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340846955.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.