OSHA Inspection: TREEHOUSE FOODS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TREEHOUSE FOODS INC. in 1080 RIVER AVENUE, PITTSBURGH, PA 15212 (NAICS 311422). OSHA activity number 340906445.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Treehouse Foods INC. — free Get an email when a new federal OSHA severe-injury report for Treehouse Foods INC. is published. One employer, no account, unsubscribe in one click.
Site address
1080 RIVER AVENUE
City
PITTSBURGH
State
PA
ZIP
15212
Mailing
1080 RIVER AVENUE, PITTSBURGH, PA 15212
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311422
Employees
483
Ownership type
A

4 citations on file for this inspection.

1910.147 D03

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Feb 9, 2016
Abate by
Mar 28, 2016
Penalty
Initial $5,500 · Current $0 Reduced
29 CFR 1910.147(d)(3):  All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  Instances including, but not limited to the following:  a) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 3, 2015, during troubleshooting operations at filler line 23A, the employer did not ensure that all energy isolating devices were located and operated prior to the work in order to control power/energy to the unit in that systems such as hot water, product and electrical were not shut off, exposing employees to burn and crushing/amputation hazards.  b) Job site, 1080 River Avenue, Pittsburgh, PA: On or about January 11, 2016, during jam clearing operations at filler line 23A, the employer did not ensure that all energy isolating devices were located and operated prior to the work in order to control power/energy to the unit in that systems such as electrical were not shut off, exposing employees to crushing/amputation hazards.  c) Job site, 1080 River Avenue, Pittsburgh, PA: On or about November 14, 2015, during changeover work at filler line 23A, the employer did not ensure that all energy isolating devices were located and operated prior to the work in order to control power/energy to the unit in that systems such as hot water, product and electrical were not shut off, exposing employees to burn and crushing/amputation hazards.  d) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 3, 2015, during sanitation/cleaning operations at filler line 23A, the employer did not ensure that all energy isolating devices were located and operated prior to the work in order to control power/energy to the unit in that systems such as hot water, product and electrical were not shut off, exposing employees to burn and crushing/amputation hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $5500
  • — Z (S) $5500

1910.147 D04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Feb 9, 2016
Abate by
Mar 28, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees.   Instances including, but not limited to the following:  a) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 3, 2015, during troubleshooting operations at filler line 23A, the employer did not ensure that lockout devices were affixed to energy isolating devices in that systems such as hot water, product and electrical were not shut off and locked out, exposing employees to burn and crushing/amputation hazards.  b) Job site, 1080 River Avenue, Pittsburgh, PA: On or about January 11, 2016, during jam clearing operations at filler line 23A, the employer did not ensure that lockout devices were affixed to energy isolating devices in that systems such as electrical were not shut off and locked out, exposing employees to crushing/amputation hazards.  c) Job site, 1080 River Avenue, Pittsburgh, PA: On or about November 14, 2015, during changeover work at filler line 23A, the employer did not ensure that lockout devices were affixed to energy isolating devices in that systems such as hot water, product and electrical were not shut off and locked out, exposing employees to burn and crushing/amputation hazards.  d) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 3, 2015, during sanitation/cleaning operations at filler line 23A, the employer did not ensure that lockout devices were affixed to energy isolating devices in that systems such as hot water, product and electrical were not shut off and locked out, exposing employees to burn and crushing/amputation hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A05

Other-than-serious 1 instance 3 exposed
Issued
Feb 9, 2016
Penalty
Initial $4,400 · Current $4,400
29 CFR 1910.212(a)(5): When the periphery of the blades of a fan was less than seven (7) feet above the floor or working level, the blades were not guarded or the guarding had openings larger than one-half (1/2) inch:      Instances including, but not limited to, the following:    a) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 4, 2015, during production activities around fill line 23 A, the employer did not ensure that fan blade guard openings were kept at an appropriate size in that the Air King industrial fan had guard openings of approximately 3/4" to 1" in the blade guard.
Recent events (3)
  • — F (O) $4400
  • — C (S) $4400
  • — Z (S) $4400

1910.22 A02

Deleted Other-than-serious 1 instance 4 exposed
Issued
Feb 9, 2016
Abate by
Feb 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(2): The floor of every workroom was not maintained in a clean and, so far as possible, a dry condition, where wet processes were used, drainage was not maintained, and false floors, platforms, mats, or other dry standing places were not provided where practicable:   a) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 4, 2015, during production activities around fill line 23 A, the employer did not ensure that work floors and surrounding areas were kept dry.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Treehouse Foods INC.'s full OSHA safety record →