PITTSBURGH, PA —
OSHA Inspection: TREEHOUSE FOODS INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TREEHOUSE FOODS INC. in 1080 RIVER AVENUE, PITTSBURGH, PA 15212 (NAICS 311422). OSHA activity number 340906445.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TREEHOUSE FOODS INC.
- Site address
- 1080 RIVER AVENUE
- City
- PITTSBURGH
- State
- PA
- ZIP
- 15212
- Mailing
- 1080 RIVER AVENUE, PITTSBURGH, PA 15212
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311422
- Employees
- 483
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 D03
- Issued
- Feb 9, 2016
- Abate by
- Mar 28, 2016
- Penalty
- Initial $5,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): Instances including, but not limited to the following: a) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 3, 2015, during troubleshooting operations at filler line 23A, the employer did not ensure that all energy isolating devices were located and operated prior to the work in order to control power/energy to the unit in that systems such as hot water, product and electrical were not shut off, exposing employees to burn and crushing/amputation hazards. b) Job site, 1080 River Avenue, Pittsburgh, PA: On or about January 11, 2016, during jam clearing operations at filler line 23A, the employer did not ensure that all energy isolating devices were located and operated prior to the work in order to control power/energy to the unit in that systems such as electrical were not shut off, exposing employees to crushing/amputation hazards. c) Job site, 1080 River Avenue, Pittsburgh, PA: On or about November 14, 2015, during changeover work at filler line 23A, the employer did not ensure that all energy isolating devices were located and operated prior to the work in order to control power/energy to the unit in that systems such as hot water, product and electrical were not shut off, exposing employees to burn and crushing/amputation hazards. d) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 3, 2015, during sanitation/cleaning operations at filler line 23A, the employer did not ensure that all energy isolating devices were located and operated prior to the work in order to control power/energy to the unit in that systems such as hot water, product and electrical were not shut off, exposing employees to burn and crushing/amputation hazards.
Recent events (3)
- — F (S) $0
- — C (S) $5500
- — Z (S) $5500
1910.147 D04 I
- Issued
- Feb 9, 2016
- Abate by
- Mar 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. Instances including, but not limited to the following: a) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 3, 2015, during troubleshooting operations at filler line 23A, the employer did not ensure that lockout devices were affixed to energy isolating devices in that systems such as hot water, product and electrical were not shut off and locked out, exposing employees to burn and crushing/amputation hazards. b) Job site, 1080 River Avenue, Pittsburgh, PA: On or about January 11, 2016, during jam clearing operations at filler line 23A, the employer did not ensure that lockout devices were affixed to energy isolating devices in that systems such as electrical were not shut off and locked out, exposing employees to crushing/amputation hazards. c) Job site, 1080 River Avenue, Pittsburgh, PA: On or about November 14, 2015, during changeover work at filler line 23A, the employer did not ensure that lockout devices were affixed to energy isolating devices in that systems such as hot water, product and electrical were not shut off and locked out, exposing employees to burn and crushing/amputation hazards. d) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 3, 2015, during sanitation/cleaning operations at filler line 23A, the employer did not ensure that lockout devices were affixed to energy isolating devices in that systems such as hot water, product and electrical were not shut off and locked out, exposing employees to burn and crushing/amputation hazards.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.212 A05
- Issued
- Feb 9, 2016
- Penalty
- Initial $4,400 · Current $4,400
General-duty citation text
29 CFR 1910.212(a)(5): When the periphery of the blades of a fan was less than seven (7) feet above the floor or working level, the blades were not guarded or the guarding had openings larger than one-half (1/2) inch: Instances including, but not limited to, the following: a) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 4, 2015, during production activities around fill line 23 A, the employer did not ensure that fan blade guard openings were kept at an appropriate size in that the Air King industrial fan had guard openings of approximately 3/4" to 1" in the blade guard.
Recent events (3)
- — F (O) $4400
- — C (S) $4400
- — Z (S) $4400
1910.22 A02
- Issued
- Feb 9, 2016
- Abate by
- Feb 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): The floor of every workroom was not maintained in a clean and, so far as possible, a dry condition, where wet processes were used, drainage was not maintained, and false floors, platforms, mats, or other dry standing places were not provided where practicable: a) Job site, 1080 River Avenue, Pittsburgh, PA: On or about September 4, 2015, during production activities around fill line 23 A, the employer did not ensure that work floors and surrounding areas were kept dry.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Treehouse Foods INC.
View Treehouse Foods INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311422)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340906445.