OSHA Inspection: PRIME-PAK FOODS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRIME-PAK FOODS, INC. in 2076 MEMORIAL PARK DRIVE, GAINESVILLE, GA 30504 (NAICS 112390). OSHA activity number 340917111.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prime-Pak Foods, INC. — free Get an email when a new federal OSHA severe-injury report for Prime-Pak Foods, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2076 MEMORIAL PARK DRIVE
City
GAINESVILLE
State
GA
ZIP
30504
Mailing
2076 MEMORIAL PARK DRIVE, GAINESVILLE, GA 30504
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
112390
Employees
200
Ownership type
A

28 citations on file for this inspection.

1910.22 A01

Deleted Serious Gravity 1 4 instances 100 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.  On or about September 14, 2015, employees were exposed to slip hazards: a.     The floor mats next to the hand wash station at the entrance to the production room were wet and slippery b.     Scattered pieces of chicken near the grinding equipment were slippery if the chicken was a thick piece of chicken that was larger than the grooves in the slip resistant shoes    On or about October 16, 2015, employees were exposed to slip hazards during third shift clean up: c.     Clumps of batter mix that were mixed with the water on the floor during clean up were slippery d.     Scattered pieces of chicken were slippery if the chicken was a thick piece of chicken that was larger than the grooves in the slip resistant shoes.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2700

1910.23 A08

Deleted Serious Gravity 5 2 instances 10 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $4,500 · Current $0 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:  On or about September 14, 2015, employees were exposed to trip hazards in that: a.     There is a hole in the floor with a partial loose grate covering it next to the wall at the grinder control box b.     There is a hole in the floor at the drain in the aisle between lines 1 and 2.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $4500

1910.24 F

Other-than-serious 2 instances 6 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $5,400 · Current $1,350 Reduced
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs:      On or about September 14, 2015, employees were exposed to trip hazards when the risers on the following were not uniform:    a. the risers on the steps to the mezzanine where the automated chicken weighing system was located on line 2 varied from 9 1/4 inches to 10 3/4 inches  b. the risers on the steps that transitioned from the fully cooked room to the oven room measured 8 1/2 inches, 6 inches, and approximately 10 inches.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $1350
  • — Z (S) $5400

1910.36 D01

Other-than-serious 1 instance 5 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $2,700 · Current $1,500 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:    On or about September 14, 2015, employees were exposed to fire hazards when the lobby exit door would not open unless the person leaving had knowledge of the special trick required to open the door.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $1500
  • — Z (S) $2700

1910.37 B04

Other-than-serious 2 instances 10 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $2,700 · Current $1,350 Reduced
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:    On or about September 14, 2015, employees were exposed to fire hazards when exits or exit signs could not been seen from the following:  a.     The main aisle between lines 1 and 2.    b.     The fryer room.      No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $1350
  • — Z (S) $2700

1910.37 B06

Other-than-serious Gravity 5 1 instance 10 exposed
Issued
Feb 25, 2016
Penalty
Initial $3,060 · Current $1,500 Reduced
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:    On or about September 14, 2015, employees were exposed to smoke hazards when the exit sign from the hallway into the breakroom was not lit.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $3060

1910.147 C04 I

Deleted Serious Gravity 10 4 instances 16 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about September 14, 2015, employees were exposed to struck-by and caught-in hazards: a.     Lockout/tagout was not used when removing the residual (dangling) meat from the grinder at the end of a run.   b.     Lockout/tagout was not used when changing the plastic bags on the line 2 bagger/sealer.   On or about October 17, 2015, employees were exposed to struck-by and caught-in hazards: c.     Lockout/tagout was not used when the clean-up crew was beginning the clean-up process by spraying the running equipment with water from hoses because it was easier to clean the machine while they were running.   d.     The automated weighing system on line 2 is not locked out at the beginning of clean-up when the operator stands at the machine and looks into every hopper to make sure that no chicken remains in the hoppers.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1910.147 C04 II C

Serious Gravity 10 4 instances 32 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.    On or about September 14, 2015, employees were exposed to struck-by, caught-in, and electrical hazards:  c.     The QA lockout summary provided to OSHA specifies yellow, red, and blue locks but does not indicate the significance of the color.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $6300

1910.147 C04 II D

Deleted Serious Gravity 10 3 instances 25 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control:   On or about September 14, 2015, employees were exposed to caught-in, struck-by, and electrical hazards when the written procedures supplied to OSHA all said to Test the electrical supply circuits and toTry to start the machine to ensure it does not run.  There was no written program. a.     the automated bagger/sealer on line two had a touch screen control which would have not been powered during lockout/tagout which would have made it impossible to try to start the machine  b.     no instructions were available for hydraulically powered equipment that was turned off and de-energized by turning the handle on the oil line.  During the walkaround, all of the hydraulically powered equipment checked could be re-energized (and the equipment would start running) by turning the handle on the oil line with the lock on it.   c.     QA and production employees did not have equipment to test the electrical supply circuits if they locked out the equipment.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D06

Serious Gravity 10 1 instance 13 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:  On or about October 17, 2015, employees were exposed to caught-in and struck-by hazards when the employees did not verify that the lock had effectively isolated the equipment from the energy source.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C05 II D

Deleted Serious Gravity 1 1 instance 13 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):  On or about October 17, 2015, employees were exposed to struck-by hazards when locks used did not include the name of the person applying the lock.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2700

1910.147 C06 I

Deleted Serious Gravity 10 1 instance 32 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   On or about September 14, 2015, employees were exposed to struck-by, caught-in, and electrical hazards when the annual audit did not include an audit of the procedures.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1910.147 C06 II

Serious Gravity 10 1 instance 22 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $0 · Current $6,300
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection:      On or about September 14, 2015, employees were exposed to struck-by, caught-in, and electrical hazards when the annual audit did not include identification of the machine or equipment.  Identification was generic such as 'conveyor'.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $0

1910.178 L04 II A

Deleted Serious Gravity 5 1 instance 15 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $5,400 · Current $0 Reduced
29 CFR 1910.178(l)(4)(ii)(A): Refresher training in relevant topics was not provided to the operator when the operator had been observed to operate the vehicle in an unsafe manner:  On or about September 14, 2015, pallet jack operators had not been provided with refresher training after using a pallet jack with a non-working horn.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $5400

1910.178 L04 II B

Deleted Serious Gravity 5 1 instance 15 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(ii)(B): Refresher training in relevant topics was not provided to the operator when the operator was involved in an accident or near-miss incident:  On or about September 14, 2015, pallet jack operator had not been provided with refresher training after an employee was injured in an incident in which the employee struck his knee on a pallet jack or the pallet jack struck the employee's knee.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 P01

Deleted Serious Gravity 5 1 instance 15 exposed
Issued
Feb 25, 2016
Abate by
Mar 2, 2016
Penalty
Initial $5,400 · Current $0 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  On or about September 14, 2015, employees were exposed to struck-by hazards when the horn on the pallet jack in use in the production area was not working.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5400

1910.212 A01

Serious Gravity 10 17 instances 20 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about September 14, 2015, employees were exposed to caught-in and struck-by hazards when the following were not guarded or were inadequately guarded:    a.  inadequate guarding at the chicken grinder hopper:  the metal bars that flip over into the hopper do not prevent an employee from reaching past the bars to the auger at the bottom of the hopper.      b.  no guarding on the sealer rollers on line three:  employees hold the top of the bag as the bag passes through the rollers.     c.  no guarding on the backup sealer rollers on line three:  employees hold the top of the bag as the bag passes through the rollers      d. there are holes in the wall of the guard that are used to attach a marker to the sealer machine where the sealer bars are located on line two.  The interlock on the doors does not work and doors are not latched.        e. Batter applicator drive on line 2 has a bent guard exposing employees to rotating equipment.       h. pinch point on conveyor as it passes over the roller on line 3 at end of scoop station    i. pinch point on conveyor as it passes over the roller on line 3 at the start of scoop station    j. pinch point on conveyor as it passes over the roller on  line 3 upstream from scoop station    k. pinch point on conveyor as it passes over the roller on  line 2 at transition from metal detector and pack out    l. pinch point on conveyor as it passes over the roller on line 2 at pack out     m. pinch point on conveyor as it passes over the roller on line 2 at the XL breader.    n. pinch point on conveyor as it passes over the roller on line 1 at the exit end of the breader where operators handle the chicken before it goes into the fryer.      o. pinch point on lay-on conveyor as it passes over the roller on line 1    p. pinch point at conveyor drive roller at entrance to the fryer on line 1    q. pinch point on conveyor as it passes over the roller on line 2 during clean up        In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $6300

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 25, 2016
Abate by
Mar 15, 2016
Penalty
Initial $4,500 · Current $4,500
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  On or about September 14, 2015, employees were exposed to amputation hazards when the grinder head exit end was not guarded.  An employee's finger was amputated by the blade when he reached into the end of the machine.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $4500

1910.212 A04

Serious Gravity 5 3 instances 4 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $4,500 · Current $4,500
29 CFR 1910.212(a)(4): Revolving drum(s), barrel(s), or container(s) were not guarded by enclosure(s) which were interlocked with the drive mechanism so that the barrel(s), drum(s), or container(s) could not revolve unless the enclosure(s) were in place:  On or about October 17, 2015, employees were exposed to caught-in hazards when the following drums were not guarded or were inadequately guarded or did not have an interlocked guard: a. drum breader on line two does not have interlocked guards over the drum and is operated during cleanup with the guards up.   b. drum tumbler on line one:  The guard on the drive mechanism is missing a nut and is not interlocked.  The gap between the guard and the drum supports permits clothing and small fingers to be trapped.  On or about September 14, 2015, employees were exposed to caught-in hazards when the following drum was not guarded or was inadequately guarded or did not have an interlocked guard: c.drum breader on line one:  the drum support rollers are not guarded and the cover is not interlocked.  Photo of additional guarding provided by the employer.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $4500

1910.212 A05

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 25, 2016
Penalty
Initial $3,600 · Current $3,600
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:  On or about September 14, 2015, employees were exposed to struck-by hazards when the exhaust hose that was designed to cover the exhaust fan blades on the sealer on line number 3 was not secured to the fan housing.  The fan blades were exposed.  The employer had attempted to use tape to hold the hose in position.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $3600

1910.335 A01 I

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  On or about September 14, 2015, employees were exposed to electrical hazards when the employees did not use any personal protective equipment when they used a meter to test a circuit to verify that it had been de-energized as part of lockout/tagout.  Voltages are 110, 220, 208, and 408.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1904.29 B01

Other-than-serious 5 instances 200 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $900 · Current $900
29 CFR 1904.29(b)(1): A Log of all recordable work-related injuries and illnesses (OSHA From 300 or equivalent), was not completed in detail as required by the regulation:  On or about September 14, 2015, the OSHA 300 logs for 2015 had the following errors: a. Case 11 dated 8/28 was not classified.  Column L was blank.  Injury (strain/abrasion) was missing from column F.  Employee had ten days of light duty. b. Case 12 dated 9/9 was not classified.  Column K and Column L were blank.  Amputation with five days away from work and ten days of light duty.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $900
  • — Z (O) $900

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Feb 25, 2016
Abate by
Mar 2, 2016
Penalty
Initial $4,500 · Current $4,500
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours.   On or about September 9, 2015, the employer did not report the finger amputation that took place on 9/9/2015 at the grinder.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $4500
  • — Z (O) $4500

1910.23 E05 I

Deleted Other-than-serious 1 instance 3 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(5)(i): Handrail(s) did not consist of a lengthwise member that was mounted directly on a wall or partition by means of a bracket attached to the lower side of the handrail:  On or about September 14, 2015, the steps on line 2 leading up to the mezzanine where the automated chicken weighing system was located had the handrails welded to the mezzanine supports.  The handrail on the right side when ascending the steps was welded in two places to the mezzanine supports.   It was necessary to lift the hand off of the handrail and move it to the other side of the support when ascending the steps because of the welds when using the handrail on the right side.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C04

Deleted Other-than-serious 1 instance 7 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:  On or about October 17, 2015, employees were exposed to smoke hazards when a fire extinguisher in the line 1 freezer room was partially discharged.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Deleted Other-than-serious 1 instance 7 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:   On or about October 17, 2015, employees were exposed to smoke hazards when a fire extinguisher in the line 1 freezer room had not been inspected on a monthly basis and was partially discharged.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 15 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  The employer failed to provide SDS or updated SDS for all chemicals used or stored at the site.  There were no SDS for a.  carbon dioxide used to flash freeze product b.  ammonia used as a refrigerant c.  food grade machine oil used on the machines.     None of the MSDS in the binder had pictograms.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H02 III

Deleted Other-than-serious 1 instance 15 exposed
Issued
Feb 25, 2016
Abate by
Mar 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(2)(iii): The employer did not provide information to the employees as to the location and availability of the written hazard communication program, and material safety data sheets required by 29 CFR 1910.1200:  Some of the employees interviewed did not know what an MSDS/SDS was.  Everyone knew where the binder was located in the break room.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Prime-Pak Foods, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340917111.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.