ATLANTA, GA —
OSHA Inspection: J & J SNACK FOODS CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of J & J SNACK FOODS CORPORATION in 720 METROPOLITAN PKWY., ATLANTA, GA 30310 (NAICS 311812). OSHA activity number 340973130.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J & J SNACK FOODS CORPORATION
- Site address
- 720 METROPOLITAN PKWY.
- City
- ATLANTA
- State
- GA
- ZIP
- 30310
- Mailing
- 720 METROPOLITAN PKWY., ATLANTA, GA 30310
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 176
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.119 D03 II
- Issued
- Apr 8, 2016
- Abate by
- May 4, 2016
- Penalty
- Initial $7,000 · Current $3,500 Reduced
0170
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. a) Engine Room: The employer failed to ensure that an eyewash/shower unit was located at the exterior area of the refrigeration room where compressor units, piping and other equipment were located. Employees were exposed to materials such as, but not limited to, ammonia while performing refrigeration maintenance on the ammonia system. In accordance with ANSI/IIAR Standard 2-2008, Section 13.3.1.4 and IIAR Bulletin 109, Section 4.10.10, 1997 edition; OSHA 29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
1910.119 J05
- Issued
- Apr 8, 2016
- Penalty
- Initial $7,000 · Current $5,000 Reduced
0170
General-duty citation text
29 CFR 1910.119(j)(5): Equipment deficiencies. (A) The employer did not correct deficiencies in equipment that were outside acceptable limits as required. a) J & J Snack Foods dba Country Home Bakers: The employer failed to ensure that the ammonia detection system containing sensors remained in an operable condition. The #2 spiral maintained an ammonia sensor that had malfunctioned. Employees were exposed to an inhalation hazard from an exposure to ammonia .
Recent events (2)
- — I (S) $5000
- — Z (S) $7000
1910.119 L02 II
- Issued
- Apr 8, 2016
- Penalty
- Initial $7,000 · Current $5,000 Reduced
0170
General-duty citation text
29 CFR 1910.119(l)(2)(ii): The employer did not establish management of change procedures to manage the impact of change on safety and health. a) J &J Snack Foods dba Country Home Bakers: The employer failed to implement a MOC (Management of Change) protocol to establish and address the impact of safety and health on employees when assigned duties involving ammonia refrigeration maintenance. The change reflects deviation from normal operating procedures of an enclosed recirculating ammonia system that included spiral #2. Piping on the high side gas line was cut off and altered from the normal defrost pan. Employees were exposed to an inhalation hazard from an exposure to ammonia .
Recent events (2)
- — I (S) $5000
- — Z (S) $7000
1910.134 E01
- Issued
- Apr 8, 2016
- Abate by
- May 4, 2016
- Penalty
- Initial $5,000 · Current $5,000
0170
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) (a) Engine Room: Employee required to utilize a tight-fitting full face respirator (MSA) while performing maintenance and repairs on an enclosed recirculating ammonia refrigeration system did not receive a medical evaluation to determine the employees ability to wear a respirator.
Recent events (2)
- — I (S) $5000
- — Z (S) $5000
1910.134 F02
- Issued
- Apr 8, 2016
- Abate by
- May 4, 2016
- Penalty
- Initial $5,000 · Current $0 Reduced
0170
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) Engine Room: Employee required to utilize a tight-fitting full face respirator (MSA) while performing maintenance and repairs on an enclosed recirculating ammonia refrigeration system did not receive a fit test.
Recent events (2)
- — I (S) $0
- — Z (S) $5000
More inspections at J & J Snack Foods Corporation
View J & J Snack Foods Corporation's full OSHA safety record →
More inspections in this industry (NAICS 311812)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340973130.