Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCHULTHEIS ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCHULTHEIS ROOFING, INC. in 395 FEDERAL STREET, PITTSBURGH, PA 15212 (NAICS 238160). OSHA activity number 340974708.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schultheis Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Schultheis Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
395 FEDERAL STREET
City
PITTSBURGH
State
PA
ZIP
15212
Mailing
1003 WRIGHT ROAD, NEW KENSINGTON, PA 15068
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
20
Ownership type
A

2 citations on file for this inspection.

1926.1053 B01

Other-than-serious 1 instance 1 exposed
Issued
Oct 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access; or, when such an extension was not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that would not deflect, and a grasping device, such as a grab rail, was not provided to assist employees in mounting and dismounting the ladder:   a) Jobsite, 395 Federal Street, Pittsburgh, PA: On or about October 6, 2015, during roofing activities, the employer did not ensure that the extension ladder, used to gain access to/egress from the loading dock roof and the ground/parking area, was extended at least 3 feet above the landing surface when extension of the ladder was possible.
Recent events (1)
  • — Z (O) $0

1926.503 C

Other-than-serious 1 instance 6 exposed
Issued
Oct 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.503(c): When the employer had reason to believe that any affected employee who has already been trained did not have the understanding and skill required by paragraph (a) of this section, the employer did not retrain each such employee:   a) Jobsite, 395 Federal Street, Pittsburgh, PA: On or about October 6, 2015, during roofing activities, the employer did not ensure that employees were retrained in fall protection where deficiencies in fall protection used existed, including, but not limited to, employees working on a roof where warning flags were permitted to lay as low as ground level or where warning flag lines were removed from their location, allowed to lay on roof level and a safety monitor was used where the building exceeded 50 feet in it's least dimension.
Recent events (1)
  • — Z (O) $0

View Schultheis Roofing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340974708.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.