CASTLE ROCK, CO —
OSHA Inspection: MASTER MAGNETICS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MASTER MAGNETICS, INC. in 747 S GILBERT ST, CASTLE ROCK, CO 80104 (NAICS 332999). OSHA activity number 341214765.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MASTER MAGNETICS, INC.
- Site address
- 747 S GILBERT ST
- City
- CASTLE ROCK
- State
- CO
- ZIP
- 80104
- Mailing
- 747 S GILBERT ST, CASTLE ROCK, CO 80104
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 40
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.106 E02 IV B
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(b): Where flammable liquids are used or handled, except in closed containers, means were not provided to dispose promptly and safely of leakage or spills: a. On or about January 28, 2016 and at times prior, employees were exposed to serious injuries from fire hazards at the dipping and coating operation and flammable storage area. Cardboard boxes were used to catch the paint drips and were left on the floor full of paint.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.106 E06 II
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with: a. On or about January 28, 2016 and at times prior, employees were exposed to fire hazards from 5-gallon containers of flammable liquids. The containers were not electrically interconnected to prevent static electrical sparks from flammable liquids to include, but not limited to: 1. Toluene - Category 2 with Flashpoint of 4°C (40°F) and Boiling Point of 111°C (231°F) 2. Sherwin-Williams Fast Acrylic Enamel - Category 2 with Flashpoint of 7°C (44.6°F) and Boiling Point of 105°C (221°F)
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.106 E07 I B
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.106(e)(7)(i)(b): Locations where flammable vapor-air mixtures may exist under normal operations shall be classified Class I, Division 1 according to the requirements of subpart S of this part. For those pieces of equipment installed in accordance with subparagraph (3)(v)(b) of this paragraph, the Division 1 area did not extend 5 feet in all directions from all points of vapor liberation. All areas within pits shall be classified Division 1 if any part of the pit is within a Division 1 or 2 classified area, unless the pit is provided with mechanical ventilation: a. On or about January 28, 2016 and at times prior, employees were exposed to fire hazards from an electrical lighting that was approximately 2 feet away from the dipping and coating operation area. The electrical lighting was not rated and approved to be used near flammable vapor-air mixtures from flammable fluids to include but not limited to: 1. Toluene - Category 2 with Flashpoint of 4°C (40°F) and Boiling Point of 111°C (231°F) 2. Sherwin-Williams Fast Acrylic Enamel - Category 2 with Flashpoint of 7°C (44.6°F) and Boiling Point of 105°C (221°F)
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.134 C01
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. On or about January 28, 2016 and at times prior, employees were required to wear 3M particulate respirators - Model 9210 while conducting dipping and coating operations. The employer did not develop and implement a respiratory protection program prior to the employees using the respirators in the workplace.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.212 A01
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about January 28, 2016 and at times prior, an employee was exposed to possible serious injuries from flying metal particles and point of operation of the vertical lathe machines. The lathe machine was not provided with a chip guard and a machine guard cover.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.215 B09
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a. On or about January 28, 2016 and at times prior, employees were exposed to possible serious injuries from a bench grinder. The tongue guard had an approximately 1/2 inch opening.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.1200 F05 I
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) On or about January 28, 2016 and at times prior, employees were exposed to possible health illness from unlabeled secondary containers: 1. Secondary container of toluene. 2. Dip tanks (paint, paint thinner, and toluene).
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.1200 F05 II
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a) On or about January 28, 2016 and at times prior, employees were exposed to possible health illness from unlabeled secondary chemical containers: 1. Secondary container of toluene. 2. Dip tanks (paint, paint thinner, and toluene).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A01
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $700 · Current $350 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: a. On or about January 28, 2016 and at times prior, the wood shop area was left with wood dust on the floor. The wood shop was not kept clean and orderly.
Recent events (2)
- — I (O) $350
- — Z (O) $700
1910.37 A03
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $700 · Current $350 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a. On or about January 28, 2016 and at times prior, an exit route located at the southwest area of Warehouse #1 was stored with packages and materials on the aisle in the packaging area. The employees working inside the warehouse were exposed to possible entrapment.
Recent events (2)
- — I (O) $350
- — Z (O) $700
1910.37 B06
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $700 · Current $350 Reduced
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: a. On or about January 28, 2016 and at times prior, employees were exposed to possible entrapment in the event of a fire. An exit sign located at the west of Warehouse #3 was not illuminated by a light source of at least five foot-candles.
Recent events (2)
- — I (O) $350
- — Z (O) $700
1910.37 B02
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a. On or about January 28, 2016 and at times prior, an exit door located at the south side of Warehouse #1 was not marked with an exit sign. The employees were exposed to possible entrapment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.37 B05
- Issued
- May 12, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a. On or about January 28, 2016 and at times prior, two doors located at the south side of Warehouse #1 were not marked with by a "Not an Exit" sign or indicating it's actual use. The doors were along the exit route and the employees could mistaken it as an exit door.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Master Magnetics, INC.
View Master Magnetics, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341214765.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.