Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MASTER MAGNETICS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MASTER MAGNETICS, INC. in 1211 ATCHISON COURT, CASTLE ROCK, CO 80109 (NAICS 332322). OSHA activity number 345129035.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Master Magnetics, INC. — free Get an email when a new federal OSHA severe-injury report for Master Magnetics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1211 ATCHISON COURT
City
CASTLE ROCK
State
CO
ZIP
80109
Mailing
1211 ATCHISON COURT, CASTLE ROCK, CO 80109
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
65
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 2, 2021
Abate by
Apr 8, 2021
Penalty
Initial $9,557 · Current $6,000 Reduced
29 CFR  1910.147(c)(1): Energy control program. The employer did not establish a program consisting of energy control procedures, employee training, and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup, or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.   (a) On or about February 2, 2021, and at times prior, employees were exposed to amputation hazards in that an effective hazardous energy control was not implemented at the facility.  The following deficiencies were observed:   1) Employees were performing a blade change on the HEM saw, model H90A, without de-energizing and isolating the machine, thus exposing them to amputation hazards in the event of an unexpected start-up.    2) When machines were locked/tagged out at times, employees performing the maintenance work are not applying their own locks/tags and are working under the lock/tags of a supervisor or facilities coordinator.  This was observed when the employer attempted to correct the lack of de-energization/isolation for the blade change operation during the inspection.  3) Employees were not adequately trained on the proper implementation of the hazardous energy control program or procedures.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $9557

1910.133 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 2, 2021
Abate by
Apr 8, 2021
Penalty
Initial $5,461 · Current $3,000 Reduced
29 CFR  1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases, or vapors, or potentially injurious light radiation:  (a) On or about February 2, 2021, the employer, Master Magnetics, Inc., did not ensure each exposed employee using the pressurized water/air hose to remove metal scraps from the metal magnet product, was protected from flying metal shavings, by use of eye protection.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5461

1910.303 G01

Other-than-serious 1 instance 10 exposed
Issued
Apr 2, 2021
Abate by
Apr 8, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a) On or about February 2, 2021, the employer, Master Magnetics, Inc., did not ensure safe access to the electrical panels was maintained. Panels were obstructed by a pallet containing forklift charging stations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Master Magnetics, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345129035.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.