Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SKANA ALUMINUM CO

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SKANA ALUMINUM CO in 2009 MIRRO DRIVE, MANITOWOC, WI 54221 (NAICS 331314). OSHA activity number 341259166.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Skana Aluminum CO — free Get an email when a new federal OSHA severe-injury report for Skana Aluminum CO is published. One employer, no account, unsubscribe in one click.
Establishment
SKANA ALUMINUM CO
Site address
2009 MIRRO DRIVE
City
MANITOWOC
State
WI
ZIP
54221
Mailing
P.O. BOX 1477, MANITOWOC, WI 54221
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331314
Employees
140
Ownership type
A

4 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 20 instances 30 exposed
Issued
Mar 15, 2016
Abate by
Apr 12, 2016
Penalty
Initial $4,950 · Current $3,465 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) On or about February 17, 2016 the employer had not conducted a periodic inspection of the established energy control procedures at least annually.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $4950

1910.147 D

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 15, 2016
Abate by
Apr 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a) On or about February 17, 2016 employees who performed setup tasks on the automatic stacker were not required to:   1) Turn off and shut down the machine(s),  2) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source,  3) affix lockout or tagout devices to each energy isolating device,  4) prior to starting work on the machine that have been locked out, verify that isolation and deenergization of the machine or equipment have been accomplished.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A02

Serious Gravity 5 2 instances 6 exposed
Issued
Mar 15, 2016
Abate by
May 16, 2016
Penalty
Initial $4,950 · Current $3,465 Reduced
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:    a) On or about February 17, 2016 the rectangular guard at the end of the conveyor feeding the automatic stacker was not affixed to the machine.     b) On or about February 8, 2016 the triangular guard at the out-feed of the shear was not affixed to the machine.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $4950

1910.212 A01

Serious Gravity 5 4 instances 6 exposed
Issued
Mar 15, 2016
Abate by
May 16, 2016
Penalty
Initial $9,900 · Current $7,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     a) On or about February 18, 2016 the in-running nip points on the ends of the stacker conveyors were not guarded to prevent employee exposure to the pinch point hazards.     b) On or about February 18, 2016 the upper portion of the shear was not guarded to prevent employee exposure to pinch point and struck-by hazards.     c) On or about February 18, 2016 the automatic stacker was not guarded on either loading side to prevent employee exposure to struck-by and/or pinch point hazard from the unguarded moving components.       Skana Aluminum Co. was previously cited for a violation of this Occupational Safety and Health Standard 1910.212(a)(1) which was contained in OSHA inspection number 1071598, citation number 1, item number 2 and was affirmed as a final order on August 27, 2015, with respect to a workplace located at 2009 Mirro Drive, Manitowoc, WI 54220.
Recent events (2)
  • — I (S) $7000
  • — Z (R) $9900

View Skana Aluminum CO's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341259166.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.