OSHA Inspection: IVC US, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of IVC US, INC. in 101 IVC DRIVE, DALTON, GA 30721 (NAICS 326192). OSHA activity number 341271690.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch IVC US, INC. for free Get an email when a new federal OSHA severe-injury report for IVC US, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
IVC US, INC.
Site address
101 IVC DRIVE
City
DALTON
State
GA
ZIP
30721
Mailing
101 IVC DRIVE, DALTON, GA 30721
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326192
Employees
325
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 10, 2016
Abate by
Mar 22, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a)  Take-up Roller Area: An employee was cleaning the take-up rollers, which had not separated, while in motion, exposing the employee to amputation and caught-in hazards. The employer developed and implemented lockout/tagout procedures but failed to utilize the procedure when cleaning the take-up rollers.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $5000

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 10, 2016
Abate by
Apr 5, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use    a)  Take-up Roller Area: Employees mixed sodium hydroxide for cleaning the rollers for the take-up area and there was no eyewash or drench station in the mixing area in case of accidental contact with eyes or skin.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $5000

View IVC US, INC.'s full OSHA safety record →