MANITOWOC, WI —
OSHA Inspection: LAKESIDE FOODS INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of LAKESIDE FOODS INC in 508 JAY STREET, MANITOWOC, WI 54220 (NAICS 311421). OSHA activity number 341337848.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LAKESIDE FOODS INC
- Site address
- 508 JAY STREET
- City
- MANITOWOC
- State
- WI
- ZIP
- 54220
- Mailing
- 510 JAY STREET, MANITOWOC, WI 54220
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311421
- Employees
- 17
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.1001 J03 I
- Issued
- Jul 15, 2016
- Abate by
- Aug 12, 2016
- Penalty
- Initial $7,000 · Current $7,000
9020
General-duty citation text
29 CFR 1910.1001(j)(3)(i): Building and facility owners shall determine the presence, location, and quantity of ACM and/or PACM at the work site. Employers and building and facility owners shall exercise due diligence in complying with these requirements to inform employers and employees about the presence and location of ACM and PACM.
Recent events (2)
- — I (S) $7000
- — Z (S) $7000
1926.1101 G04 II A
- Issued
- Jul 15, 2016
- Abate by
- Aug 12, 2016
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1926.1101(g)(4)(ii)(A): For all Class I jobs involving the removal of more than 25 linear or 10 square feet of thermal system insulation or surfacing material; for other Class I jobs where the employer could not produce a negative exposure assessment pursuant to 29 CFR 1926.1101(f)(2)(iii), or where employees were working in areas adjacent to the regulated area, while the Class I work was being performed, the employer did not use critical barriers placed over all the openings to the regulated area, except where activities were being performed outdoors: a. On or about February 23, 2016, the employer did not place critical barriers over all openings to the regulated area where Class I work involving the removal of Thermal System Insulation (TSI) at the facility located at 508 Jay Street Manitowoc, WI 54220.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1001 J03 II
- Issued
- Jul 15, 2016
- Abate by
- Aug 12, 2016
- Penalty
- Initial $7,000 · Current $7,000
9020
General-duty citation text
29 CFR 1910.1001(j)(3)(ii): Building and facility owners shall maintain records of all information required to be provided pursuant to this section and/or otherwise known to the building owner concerning the presence, location and quantity of ACM and PACM in the building/facility. Such records shall be kept for the duration of ownership and shall be transferred to successive owners.
Recent events (2)
- — I (S) $7000
- — Z (S) $7000
1926.1101 F03 I
- Issued
- Jul 15, 2016
- Abate by
- Aug 12, 2016
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1926.1101(f)(3)(i): The employer failed to conduct daily monitoring that was representative of the exposure of each employee assigned to work in regulated areas and performing Class I or II work: a. On or about, February 23, 2016, the employer did not conduct daily monitoring of maintenance employees who were assigned to work in a regulated area performing Class I work removing Thermal System Insulation (TSI) at the facility located at 508 Jay Street Manitowoc, WI 54220. Note: Employers who complete a negative exposure assessment in accordance with paragraph (f)(2)(iii) do not need to conduct the daily monitoring for activity covered by the assessment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1101 H01 I
- Issued
- Jul 15, 2016
- Abate by
- Aug 12, 2016
- Penalty
- Initial $7,000 · Current $0 Reduced
9020
General-duty citation text
29 CFR 1926.1101(h)(1)(i): Respirators were not used during all Class I asbestos jobs: a. On or about, February 23, 2016, the employer did not ensure that maintenance employees were using respirators when performing Class I work removing Thermal System Insulation (TSI) at the facility located at 508 Jay Street Manitowoc, WI 54220.
Recent events (2)
- — I (S) $0
- — Z (S) $7000
1926.1101 I01
- Issued
- Jul 15, 2016
- Abate by
- Aug 12, 2016
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1926.1101(i)(1): The employer did not provide or require the use of protective clothing such as coveralls or similar whole-body clothing, head coverings, gloves, and foot coverings for employees performing Class I work which involved the removal of over 25 linear or 10 square feet of thermal system insulation or surfacing asbestos containing material and presumed asbestos containing material: a. On or about, February 23, 2016, the employer did not provide and require the use of protective clothing, such as coveralls or similar whole-body clothing, head coverings, gloves and foot coverings when maintenance employees were engaged in Class I asbestos work removing Thermal System Insulation (TSI) in an area that did not have a negative exposure assessment produced by the employer at the facility located at 508 Jay Street Manitowoc, WI 54220.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1101 J01 I
- Issued
- Jul 15, 2016
- Abate by
- Aug 12, 2016
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1926.1101(j)(1)(i): The employer did not establish a decontamination area, consisting of an equipment room, shower area, and clean room in series, adjacent and connected to the regulated area:Note: This requirement applies to Class I operations involving over 25 linear or 10 square feet of thermal system insulation or surfacing containing asbestos-containing material or presumed asbestos-containing material. a. On or about, February 23, 2016, the employer did not establish a decontamination area adjacent and connected to the work area for maintenance employees who were engaged in Class I asbestos work removing Thermal System Insulation (TSI) at the facility located at 508 Jay Street Manitowoc, WI 54220.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1101 K02 I
- Issued
- Jul 15, 2016
- Abate by
- Aug 12, 2016
- Penalty
- Initial $7,000 · Current $0 Reduced
9020
General-duty citation text
29 CFR 1926.1101(k)(2)(i): Before work subject to this standard began, the building and/or facility owner(s) did not determine the presence, location and quantity of asbestos containing material (ACM) and/or presumed asbestos containing material (PACM) at the worksite pursuant to 29 CFR 1926.1101(k)(1): a. On or about, February 23, 2016, the building and facility owners of the facility located at 508 Jay Street Manitowoc, WI 54220 had not determined the presence, location, and quantity of ACM and/or PACM in the building that they have owned since 1887.
Recent events (2)
- — I (S) $0
- — Z (S) $7000
1926.1101 K03 I
- Issued
- Jul 15, 2016
- Abate by
- Aug 12, 2016
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1926.1101(k)(3)(i): Before the employer permitted its own employees to perform work subject to this standard in areas containing asbestos-containing material (ACM) and presumed asbestos-containing material (PACM), the employer did not identify the presence, location and quantity of asbestos containing material and/or presumed asbestos containing material therein pursuant to 29 CFR 1926.1101(k)(1): a. On or about, February 23, 2016, the employer of the facility located at 508 Jay Street Manitowoc, WI 54220 had not determined the presence, location, and quantity of ACM and/or PACM in the building that they have owned since 1887.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1101 K09 II
- Issued
- Jul 15, 2016
- Abate by
- Aug 12, 2016
- Penalty
- Initial $7,000 · Current $0 Reduced
9020
General-duty citation text
29 CFR 1926.1101(k)(9)(ii): Training was not provided prior to or at the time of initial assignment and/or at least annually thereafter for employees likely to be exposed in excess of a permissible exposure limit (PEL) and for employees performing Class I through IV asbestos operations: a. On or about, February 23, 2016, the employer did not provide maintenance employees with training at the time of their initial assignment of Class I asbestos work removing Thermal System Insulation (TSI) in an area of the facility located at 508 Jay Street Manitowoc, WI 54220.
Recent events (2)
- — I (S) $0
- — Z (S) $7000
More inspections at Lakeside Foods INC
View Lakeside Foods INC's full OSHA safety record →
More inspections in this industry (NAICS 311421)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341337848.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.