MORAINE, OH ·
OSHA Inspection: FUYAO GLASS AMERICA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FUYAO GLASS AMERICA, INC. in 2801 W. STROOP RD, MORAINE, OH 45439 (NAICS 327215). OSHA activity number 341387785.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FUYAO GLASS AMERICA, INC.
- Site address
- 2801 W. STROOP RD
- City
- MORAINE
- State
- OH
- ZIP
- 45439
- Mailing
- 2801 W. STROOP RD, MORAINE, OH 45439
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327215
- Employees
- 1000
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.36 G01
- Issued
- Jul 27, 2016
- Abate by
- Jun 1, 2017
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.36(g)(1): The ceiling of an exit route must be at least seven feet six inches (2.3 m) high. Any projection from the ceiling must not reach a point less than six feet eight inches (2.0 m) from the floor: (a) The exit route out of the PVB room had three different locations where the ceiling was only 62 inches above the route of travel.
Recent events (3)
- · F (S) $5000
- · C (S) $7000
- · Z (S) $7000
1910.37 B01
- Issued
- Jul 27, 2016
- Abate by
- Jun 1, 2017
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(b)(1): Each exit route must be adequately lighted so that an employee with normal vision can see along the exit route. (a) The exit route employees must follow to leave the PVB Room in an emergency was not adequately lit, in that there was no emergency lighting if and when the power should go out.
Recent events (3)
- · F (S) $0
- · C (S) $7000
- · Z (S) $7000
1910.37 B02
- Issued
- Jul 27, 2016
- Abate by
- Jun 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit:" (a) There were no exit signs in the PVB Room, the Inspection Room or the Stretch Room.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.37 B04
- Issued
- Jul 27, 2016
- Abate by
- Jun 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(4): If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge. Additionally, the line-of-sight to an exit sign must clearly be visible at all times. (a) Direction of travel signs were not posted along the exit route from the PVB Room to the main factory floor. (b) Direction of travel signs were incorrectly posted by Pillar AE 40, in that the exit sign pointed toward a temporary fenced in storage area that did not have an exit.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.37 E
- Issued
- Jul 27, 2016
- Abate by
- Jun 1, 2017
- Penalty
- Initial $7,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.37(e): An employee alarm system must be operable. Employers must install and maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other emergencies, unless employees can promptly see or smell a fire or other hazard in time to provide adequate warning to them. The employee alarm system must comply with �� 1910.165. [39 FR 23502, June 27, 1974, as amended at 45 FR 60703, Sept. 12, 1980; 67 FR 67963, Nov. 7, 2002]: (a) Employees working in the PVB Room were not protected by a fire alarm system or an effective employee alarm system.
Recent events (3)
- · F (S) $2500
- · C (S) $7000
- · Z (S) $7000
More inspections at Fuyao Glass America, INC.
View Fuyao Glass America, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327215)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341387785.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.