OSHA Inspection: FUYAO GLASS AMERICA, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FUYAO GLASS AMERICA, INC in 2801 W STOOP RD, DAYTON, OH 45439 (NAICS 327211). OSHA activity number 348370321.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fuyao Glass America, INC — free Get an email when a new federal OSHA severe-injury report for Fuyao Glass America, INC is published. One employer, no account, unsubscribe in one click.
Site address
2801 W STOOP RD
City
DAYTON
State
OH
ZIP
45439
Mailing
2801 W STOOP RD, DAYTON, OH 45439
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327211
Employees
2468
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 3, 2025
Abate by
Jan 22, 2026
Penalty
Initial $16,550 · Current $16,550
29 CFR  1910.147(c)(4)(i):Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   a) On or about 07/05/2025, the employer did not ensure that the lock out tag out procedures for the lamination autoclaves in the coating plant were utilized to lockout the electrical energy in that employees were oiling conveyor chains in the autoclave while the chains on the conveyor system were energized exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $16550
  • — Z (S) $16550

1910.147 D

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 3, 2025
Abate by
Jan 22, 2026
Penalty
Initial $16,550 · Current $0 Reduced
29 CFR  1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  (1) Preparation for shutdown. Before an authorized or affected employee turns off a machine or equipment, the authorized employee shall have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy. (2) Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage. (3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). (4) Lockout or tagout device application. (4)(i) Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. (5) Stored energy. (i) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe. (d)(6) Verification of isolation. Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished.  a) On or about 07/05/2025, the employer did not ensure that employees lubricating the conveyor chains for the lamination autoclave in the coating plant performed (d1-d6) of the requirements to ensure all energy sources such as the electrical energy sources and the pneumatic energy sources were secured to prevent exposing employees to caught in hazards from the energized conveyor chains while brushing lubricant on the chains.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16550

1910.147 C07 I A

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 3, 2025
Abate by
Jan 22, 2026
Penalty
Initial $16,550 · Current $0 Reduced
29 CFR  1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.   a) On or about 07/05/2025, the employer did not ensure that authorized employees lubricating the conveyor chains for the lamination autoclaves in the coating plant were trained in the methods and means necessary for energy isolation of the electrical and pneumatic energy sources to deenergize the conveyor chains exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16550

View Fuyao Glass America, INC's full OSHA safety record →