Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S DEPARTMENT OF INTERIOR - NATIONAL PARK SERVICE (NPS) - PINNACLES NATIONAL PARK

Special Programs inspection · Safety discipline

On , OSHA opened a special Programs safety inspection of U.S DEPARTMENT OF INTERIOR - NATIONAL PARK SERVICE (NPS) - PINNACLES NATIONAL PARK in 5000 HIGHWAY 146, PAICINES, CA 95043 (NAICS 712190). OSHA activity number 341454023.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S Department of Interior - National Park Service (NPS) - Pinnacles National Park — free Get an email when a new federal OSHA severe-injury report for U.S Department of Interior - National Park Service (NPS) - Pinnacles National Park is published. One employer, no account, unsubscribe in one click.
Site address
5000 HIGHWAY 146
City
PAICINES
State
CA
ZIP
95043
Mailing
5000 HIGHWAY 146, PAICINES, CA 95043
Inspection type
Special Programs (K)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
60
Ownership type
D

14 citations on file for this inspection.

1910.132 A

Serious Gravity 1 3 instances 5 exposed
Issued
Aug 26, 2016
Abate by
Sep 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.132(a): Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.  (a) Maintenance Shop: Personal Protective Equipment such as ear muffs, face shields, and welding goggles were not maintained in a sanitary and reliable condition. The muffs were stored on top of a cut off saw. The goggles were stored on top of gas welding equipment. The face shield was placed on the wall, out in the open.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Serious Gravity 1 2 instances 5 exposed
Issued
Aug 26, 2016
Abate by
Sep 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a) Caterpiller, Backhoe Loader: A portable 2.5 LB multi-purpose dry chemical fire extinguisher was not mounted. It was laying on the equipment floor. It was designed to be mounted it in the battery box.    (b) Maintenance Warehouse: A portable 20 LB multi-purpose dry chemical fire extinguisher was not mounted. It was standing on the working room floor. It was designed to be mounted on metal brackets or in wall cabinets at lower heights with the carrying handle about 3 feet from the floor.
Recent events (1)
  • — Z (S) $0

1910.157 E02

Serious Gravity 1 2 instances 5 exposed
Issued
Aug 26, 2016
Abate by
Sep 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section was not visually inspected monthly.  (a) Caterpiller, Backhoe Loader: A portable 2.5 LB multi-purpose dry chemical fire extinguisher was not inspected monthly. It was laying on the equipment floor.  (b) Maintenance Warehouse: A portable 20 LB multi-purpose dry chemical fire extinguisher was not inspected monthly. It was standing on the working room floor.
Recent events (1)
  • — Z (S) $0

1910.178 L04 III

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 26, 2016
Abate by
Sep 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years.  (a) Chalone, Maintenance Building Area (east Side): Back hoe operators were not re-evaluated or received an operator evaluation at least once every three years.
Recent events (1)
  • — Z (S) $0

1910.178 M05 I

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 26, 2016
Abate by
Sep 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(m)(5)(i): When a powered industrial truck is left unattended, load engaging means were not fully lowered, controls shall be neutralized, power shall be shut off, and brakes set. Wheels shall be blocked if the truck is parked on an incline.  (a) Chalone, Maintenance Building Area (East Side): Caterpillar Back hoe Model 416D, outriggers were not lowered to prevent possibly being struck by falling outriggers. Employees were exposed to struck by hazards
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 26, 2016
Abate by
Sep 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Trail Shop: Employees were exposed to caught in hazards while working on Delta R8827 Vertical Drill Press, Cat No. 17-900 that was not provided with an unguarded chuck.
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 26, 2016
Abate by
Sep 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Anchoring fixed machinery. Machines designed for a fixed location were not securely anchored to prevent walking or moving.  (a) Trail Shop:  A Delta drill press was not mounted to the concrete floor to prevent walking or moving. Operators of the drill were exposed to possibly getting struck by the rotating unguarded chuck and moving equipment.
Recent events (1)
  • — Z (S) $0

1910.213 C01

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 26, 2016
Abate by
Sep 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(1): Each circular hand-fed ripsaw was not guarded by a hood which was completely enclose that portion of the saw above the table and that portion of the saw above the material being cut.   (a) Maintenance Shop: Delta 10 inch tilting arbor Unisaw was not provided with a guard hood adjust to the thickness of the materials being cut and remain in contact with it. Employees were exposed to amputation related injuries.
Recent events (1)
  • — Z (S) $0

1910.213 C02

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 26, 2016
Abate by
Sep 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(2): Each hand-fed circular ripsaw was not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator.   (a) Maintenance Shop: The 10 inch Delta Tilting Arbor Unisaw was not provided with a spreader to prevent material from squeezing the saw blade to prevent the materials thrown back to the operator of the saw. The operators were exposed to struck by hazards.
Recent events (1)
  • — Z (S) $0

1910.213 C03

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 26, 2016
Abate by
Sep 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3): Each hand-fed circular ripsaw was not provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of materials being cut.  (a) Maintenance Shop: The right and left side portion of the saw blade on the Delta 10 inch tilting arbor Unisaw was not provided with non-kickback fingers or dogs to hold all the thicknesses of material being cut. Employees were exposed to struck by related injuries.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 1 2 instances 5 exposed
Issued
Aug 26, 2016
Abate by
Sep 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rests. On off hand grinding machines, work rests were not used to support the work. The work rests were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage.    (a) Maintenance Shop: A DeWalt bench grinder work rests were not adjusted to maintain a minimum of 1/8 inch to prevent the work from being jammed between the wheel and the work rest.  (b) Trail Shop: A Wissota ball bearing bench grinder work rests were not adjusted to maintain a minimum of 1/8 inch to prevent the work from being jammed between the wheel and the work rest.
Recent events (1)
  • — Z (S) $0

1910.253 B04 I

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 26, 2016
Abate by
Sep 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were not to be stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment.    (a) Maintenance Shop: Two oxygen bottles considered to be in use were not stored away from a can of oil. It was stored approximately 14 inches from the bottles.  Employees were possibly exposed to explosion and fire.
Recent events (1)
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 26, 2016
Abate by
Sep 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.  (a) Maintenance Shop: Wall mounted electrical receptacle was not provided with a faceplate. Employees were exposed to electric shock or born related hazards.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 26, 2016
Abate by
Sep 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) Maintenance Shop: Flexible cord was not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.
Recent events (1)
  • — Z (S) $0

View U.S Department of Interior - National Park Service (NPS) - Pinnacles National Park's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341454023.