Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S DEPARTMENT OF INTERIOR - NATIONAL PARK SERVICE (NPS) - PINNACLES NATIONAL PARK EAST

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S DEPARTMENT OF INTERIOR - NATIONAL PARK SERVICE (NPS) - PINNACLES NATIONAL PARK EAST in 5000 HIGHWAY 146, PAICINES, CA 95043 (NAICS 712190). OSHA activity number 344305933.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S Department of Interior - National Park Service (NPS) - Pinnacles National Park East — free Get an email when a new federal OSHA severe-injury report for U.S Department of Interior - National Park Service (NPS) - Pinnacles National Park East is published. One employer, no account, unsubscribe in one click.
Site address
5000 HIGHWAY 146
City
PAICINES
State
CA
ZIP
95043
Mailing
5000 HIGHWAY 146, PAICINES, CA 95043
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
35
Ownership type
D

7 citations on file for this inspection.

1910.303 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Examination, installation, and use of equipment -- Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  Conference Room / Admin Break Room: Two power strips were not being used in accordance with any instructions included in the listing or labeling. The power strips were daisy-chained and one of them was being used to power a microwave and a small water heater.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 30, 2019
Abate by
Oct 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   Rangers Office Building: An electrical panel was blocked and was not visible. Employees were exposed to electrical related hazards.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Repeat Gravity 1 1 instance 3 exposed
Issued
Sep 30, 2019
Abate by
Oct 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  Chalone Maintenance Shop, Work Shop: A portable multi-purpose dry chemical fire extinguisher was not mounted. It was standing on the working room floor near an exit door. Employees were exposed to tripping hazards.  The National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.157(c)(1), which was contained in OSHA inspection number 1145402, citation number 01, item number 2/a and was affirmed as a final order on 09/26/2016, with respect to a workplace located at 5000 Hwy 146, Paicines, CA 95043.
Recent events (1)
  • — Z (R) $0

1910.212 A01

Repeat Gravity 1 1 instance 2 exposed
Issued
Sep 30, 2019
Abate by
Oct 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Chalone Maintenance Shop, Work Shop: Employees were exposed to point of operation and flying chips hazards while working on JET 12 inch Vertical Drill Press, Model No. JWDP-12 that was not provided with a guarded chuck.  The National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1145402, citation number 01, item number 4 and was affirmed as a final order on 09/26/2016, with respect to a workplace located at 5000 Hwy 146, Paicines, CA 95043.
Recent events (1)
  • — Z (R) $0

1910.212 B

Repeat Gravity 1 1 instance 3 exposed
Issued
Sep 30, 2019
Abate by
Oct 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Anchoring fixed machinery. Machines designed for a fixed location were not securely anchored to prevent walking or moving.  Chalone Maintenance Shop: A JET 12 inch drill press was not anchored to the work bench to prevent tipping or moving. Employees were exposed to struck by related hazards.  The National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(b), which was contained in OSHA inspection number 1145402, citation number 01, item number 5 and was affirmed as a final order on 09/26/2016, with respect to a workplace located at 5000 Hwy 146, Paicines, CA 95043.
Recent events (1)
  • — Z (R) $0

1910.213 C01

Repeat Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2019
Abate by
Oct 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(1): Each circular hand-fed ripsaw was not guarded by a hood which was completely enclose that portion of the saw above the table and that portion of the saw above the material being cut.   Chalone Maintenance Shop, Work Shop: Grizzly 10 inch Table Saw Model G1023RL was not provided with a blade guard that adjust to the thickness of the materials being cut and remain in contact with it. Employees were exposed to amputation related injuries.                                       The National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.213(c)(1), which was contained in OSHA inspection number 1145402, citation number 01, item number 6/a and was affirmed as a final order on 09/26/2016, with respect to a workplace located at 5000 Hwy 146, Paicines, CA 95043.
Recent events (1)
  • — Z (R) $0

1910.242 B

Other-than-serious 2 instances 2 exposed
Issued
Sep 30, 2019
Abate by
Oct 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 P.S.I.:   Maintenance Storage Shop: The compressed air used to clean their equipment was not reduced to 30 p.s.i., the compressed air was measured above 85 P.S.I. Employees were exposed to flying debris.
Recent events (1)
  • — Z (O) $0

View U.S Department of Interior - National Park Service (NPS) - Pinnacles National Park East's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344305933.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.