Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S DEPARTMENT OF INTERIOR - NATIONAL PARK SERVICE (NPS) - PINNACLES NATIONAL PARK, EAST

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S DEPARTMENT OF INTERIOR - NATIONAL PARK SERVICE (NPS) - PINNACLES NATIONAL PARK, EAST in 5000 HIGHWAY 146, EAST, PAICINES, CA 95043 (NAICS 712190). OSHA activity number 347491730.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S Department of Interior - National Park Service (NPS) - Pinnacles National Park, East — free Get an email when a new federal OSHA severe-injury report for U.S Department of Interior - National Park Service (NPS) - Pinnacles National Park, East is published. One employer, no account, unsubscribe in one click.
Site address
5000 HIGHWAY 146, EAST
City
PAICINES
State
CA
ZIP
95043
Mailing
5000 HIGHWAY 146, PAICINES, CA 95043
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
41
Ownership type
D

4 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 13, 2024
Abate by
Jul 11, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): When the eyes or body of any person were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  Water Treatment Building: On and /or before 05/14/2024 Suitable facilities for quick drenching or flushing of the eyes were not provided in the immediate work area for emergency use for employees adding  liquid chlorine to the water system. This condition potentially exposed employee(s) to eye irritation and/or moderate to severe chemical burns.
Recent events (1)
  • — Z (S) $0

1910.213 C01

Repeat Gravity 5 1 instance 1 exposed
Issued
Jun 13, 2024
Abate by
Jul 11, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(1): Each circular hand-fed ripsaw was not guarded by a hood which was completely enclose that portion of the saw above the table and that portion of the saw above the material being cut.   Maintenance office / Storage:  On or before 05/14/2024 a Bosch 10 inch table saw model GTA47W was not provided with a blade guard that adjust to the thickness of the materials being cut and remain in contact with it. Employees were exposed to amputation related injuries.                                       The National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.213(c)(1), which was contained in OSHA inspection number 1430593, citation number 02, item number 04 and was affirmed as a final order on 10/25/2019, with respect to a workplace located at 5000 Hwy 146, Paicines, CA 95043.
Recent events (1)
  • — Z (R) $0

1910.303 B02

Repeat Gravity 1 1 instance 1 exposed
Issued
Jun 13, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Examination, installation, and use of equipment -- Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  Conference Room / Admin Break Room:  On or before 05/14/2024 one power strips were not being used in accordance with any instructions included in the listing or labeling. The power strip was being used to power a Sharp microwave.  The National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 1430593, citation number 01, item number 01 and was affirmed as a final order on 10/25/2019, with respect to a workplace located at 5000 Hwy 146, Paicines, CA 95043.
Recent events (1)
  • — Z (R) $0

1910.303 G01

Repeat Gravity 1 1 instance 1 exposed
Issued
Jun 13, 2024
Abate by
Jul 11, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    Maintenance office / Storage: On or before 05/14/2024  An electrical panel was blocked and was not visible. Employees were exposed to electrical related hazards.  The National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(g)(1), which was contained in OSHA inspection number 1430593, citation number 01, item number 02 and was affirmed as a final order on 10/25/2019, with respect to a workplace located at 5000 Hwy 146, Paicines, CA 95043.
Recent events (1)
  • — Z (R) $0

View U.S Department of Interior - National Park Service (NPS) - Pinnacles National Park, East's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347491730.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.