NELLIS AFB, NV —
OSHA Inspection: US AIR FORCE, NELLIS AIR FORCE BASE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of US AIR FORCE, NELLIS AIR FORCE BASE in BLDG. 802, 6020 BEALE AVENUE, NELLIS AFB, NV 89191 (NAICS 928110). OSHA activity number 341461150.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- US AIR FORCE, NELLIS AIR FORCE BASE
- Site address
- BLDG. 802, 6020 BEALE AVENUE
- City
- NELLIS AFB
- State
- NV
- ZIP
- 89191
- Mailing
- 99 ABW/SE 4430 GRISSOM AVENUE, STE 206, NELLIS AFB, NV 89191
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 7
- Ownership type
- D
Citations
5 citations on file for this inspection.
1910.23 C01
- Issued
- Jun 17, 2016
- Abate by
- Jul 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toe boards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. (a) At the Fuels Building 802 mezzanine floor, the walking surface directly on top of the door where employees walk to get access to the fuels shop did not have a toe board.
Recent events (1)
- — Z (S) $0
1910.23 E01
- Issued
- Jun 17, 2016
- Abate by
- Jul 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: (a) At the Fuels Building 802 mezzanine floor, the top and the mid-rails installed were not standard in height.
Recent events (1)
- — Z (S) $0
1910.157 E02
- Issued
- Jun 17, 2016
- Abate by
- Jul 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: (a) At the Fuels Building 802, portable fire extinguisher mounted by the mezzanine stairways, was not inspected monthly. The last inspection date on the tag was January 2015.
Recent events (1)
- — Z (S) $0
1910.305 A02 IX
- Issued
- Jun 17, 2016
- Abate by
- Jul 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard: (a) At Building 874, Plumbing Water Shop Break room area, the hot dog grill's incandescent light bulb did not have a cover.
Recent events (1)
- — Z (S) $0
1910.334 A02 II
- Issued
- Jun 17, 2016
- Abate by
- Jul 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: (a) At the Fuels Building 802 mezzanine floor, the orange extension used to extend power to the yellow cord for the shop had torn insulation, the outer sheathing was separating from the connector. The US Air Force, Nellis Air Force Base was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.334(a)(2)(ii), which was contained in OSHA inspection number 536678, citation number 1, item number 3b and was affirmed as a final order on 10/26/2012 with respect to a workplace located at Nellis AFB, HVAC Shop.
Recent events (1)
- — Z (R) $0
More inspections at US AIR Force, Nellis AIR Force Base
View US AIR Force, Nellis AIR Force Base's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341461150.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.