NELLIS AFB, NV —
OSHA Inspection: US AIR FORCE, NELLIS AIR FORCE BASE
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of US AIR FORCE, NELLIS AIR FORCE BASE in 6020 BEALE AVENUE, NELLIS AFB, NV 89191 (NAICS 928110). OSHA activity number 341482594.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- US AIR FORCE, NELLIS AIR FORCE BASE
- Site address
- 6020 BEALE AVENUE
- City
- NELLIS AFB
- State
- NV
- ZIP
- 89191
- Mailing
- 99 ABW/SE 4430 GRISSOM AVENUE, STE 206, NELLIS AFB, NV 89191
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 12
- Ownership type
- D
Citations
2 citations on file for this inspection.
1910.101 B
- Issued
- Aug 18, 2016
- Abate by
- Sep 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which was incorporated by reference as specified in 29 CFR 1910.6: (a) Maintenance Yard, employees were exposed to explosion hazards by not firmly securing compressed Nitrogen cylinder to prevent falling or being knocked over.
Recent events (1)
- — Z (S) $0
1910.151 C
- Issued
- Aug 18, 2016
- Abate by
- Sep 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) Maintenance Yard, employees were exposed to injuries to eyes while working on and around corrosive battery acid and the emergency drenching system was blocked by material and was not readily available. (b) Battery Room, employees were exposed to injuries to eyes while working on and around corrosive battery acid and the emergency drenching system was blocked by material and was not readily available. THE U.S. AIR FORCE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 967340, CITATION 03, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON OCTOBER 14, 2014, WITH RESPECT TO A WORKPLACE LOCATED AT BUILDING 803, TRAVIS AIR FORCE BASE, CALIFORNIA 94535.
Recent events (1)
- — Z (R) $0
More inspections at US AIR Force, Nellis AIR Force Base