MANSFIELD, OH —
OSHA Inspection: MILARK INDUSTRIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MILARK INDUSTRIES, INC. in 128 RUPP ROAD, MANSFIELD, OH 44903 (NAICS 336370). OSHA activity number 341589836.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MILARK INDUSTRIES, INC.
- Site address
- 128 RUPP ROAD
- City
- MANSFIELD
- State
- OH
- ZIP
- 44903
- Mailing
- 536 SOUTH AIRPORT ROAD, MANSFIELD, OH 44903
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- Employees
- 280
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Oct 21, 2016
- Abate by
- Nov 1, 2016
- Penalty
- Initial $12,471 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: A) Milark Industries, Inc., located at 128 Rupp Road, Mansfield, OH 44903: On or about April 22, 2016, the employer did not properly train employees to lockout/tagout equipment such as, but not limited to, the J8 Comco Bender # 100308 (Model KB-50NT; Serial # K-02Z). Employees did not control multiple hazardous energy sources, such as electrical and hydraulic, before employees conducted activities such as, but not limited to, setting up the clamp. J8 Comco Bender # 100308 was not isolated from electrical and hydraulic energy sources prior to engaging in this maintenance activity, which exposed employees to amputation hazards.
Recent events (3)
- — F (S) $0
- — C (S) $12471
- — Z (S) $12471
1910.147 D03
- Issued
- Oct 21, 2016
- Abate by
- Mar 1, 2018
- Penalty
- Initial $124,709 · Current $80,000 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): The employer did not protect employees from the hazardous energy of machinery or equipment by turning off or shutting down machinery or equipment as required by energy control procedures, ensuring energy isolation devices were operated to isolate machinery or equipment from their energy source(s), and affixing lockout devices to energy isolation devices by authorized employees: A) Milark Industries, Inc., located at 128 Rupp Road, Mansfield, OH 44903: On or about April 22, 2016, the employer did not ensure that employees located all energy isolating devices of the J8 Comco Bender # 100308 (Model KB-50NT; Serial # K-02Z), located in the bending department, and operated those devices in such a manner as to isolate the J8 Comco Bender # 100308 from allowing employees to conduct maintenance activities such as, but not limited to, setting up the clamp. The J8 Comco Bender # 100308 was not isolated from electrical and hydraulic energy sources prior to engaging in this maintenance activity, exposing employees to amputation hazards. As a result, the remaining applicable energy control elements, involving lock-out/tag-out device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)], and verification of isolation [1910.147(d)(6)], were not implemented to protect employees from machine servicing hazards such as, but not limited to, setting up a clamp. To abate this violation, the employer must ensure that machinery or equipment are turned off or shut down, energy isolation devices are operated in a manner to isolate the machinery or equipment from the energy source(s), and lockout devices are affixed to energy isolation devices as part of the hazardous energy control process for servicing and maintenance activities including, but not limited to, setting up a clamp.
Recent events (3)
- — F (W) $80000
- — C (W) $124709
- — Z (W) $124709
1910.147 D04
- Issued
- Oct 21, 2016
- Abate by
- Mar 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4): A lockout device was not attached to all power sources: The employer did not protect employees from the hazardous energy of machinery or equipment by turning off or shutting down machinery or equipment as required by energy control procedures, ensuring energy isolation devices were operated to isolate machinery or equipment from their energy source(s), and affixing lockout devices to energy isolation devices by authorized employees: A) Milark Industries, Inc., located at 128 Rupp Road, Mansfield, OH 44903: On or about April 22, 2016, the employer did not ensure that employees applied lockout/tagout devices in order to control hazardous energy of the J8 Comco Bender # 100308 (Model KB-50NT; Serial # K-02Z), located in the bending department, prior to allowing employees to conduct maintenance activities such as, but not limited to, setting up the clamp. The J8 Comco Bender # 100308 was not isolated from electrical and hydraulic energy sources prior to engaging in this maintenance activity, exposing employees to amputation hazards. As a result, the remaining applicable energy control elements, involving dissipation of residual energy [1910.147(d)(5)], and verification of isolation [1910.147(d)(6)], were not implemented to protect employees from machine servicing hazards such as, but not limited to, setting up a clamp. To abate this violation, the employer must ensure that machinery or equipment are turned off or shut down, energy isolation devices are operated in a manner to isolate the machinery or equipment from the energy source(s), and lockout devices are affixed to energy isolation devices as part of the hazardous energy control process for servicing and maintenance activities including, but not limited to, setting up a clamp.
Recent events (3)
- — F (W) $0
- — C (W) $0
- — Z (W) $0
More inspections at Milark Industries, INC.
View Milark Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336370)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341589836.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.