OSHA Inspection: QUALITY WELDING & FABRICATION, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of QUALITY WELDING & FABRICATION, LLC in 4330 EAST RD., ELIDA, OH 45807 (NAICS 332999). OSHA activity number 341601664.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Welding & Fabrication, LLC for free Get an email when a new federal OSHA severe-injury report for Quality Welding & Fabrication, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4330 EAST RD.
City
ELIDA
State
OH
ZIP
45807
Mailing
4330 EAST RD., ELIDA, OH 45807
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
35
Ownership type
Private (A)

8 citations on file for this inspection.

1910.107 C02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2016
Penalty
Initial $6,236 · Current $0 Reduced
29 CFR 1910.107(c)(2): Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.   a) On or about July 6, 2016 the employer failed to ensure that there was no spark producing equipment within 20 feet of the spraying area.  A pole barn used as a spray area; electrical outlets and uncovered lights were in the spray area.  They were not designed for use in a Class I Division II hazardous location.
Recent events (3)
  • · J (S) $0
  • · C (S) $6236
  • · Z (S) $6236

1910.107 D02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2016
Penalty
Initial $6,236 · Current $0 Reduced
29 CFR 1910.107(d)(2): Spraying area(s) were not provided with mechanical ventilation adequate to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues:   a.) On or about July 6, 2016 the employer did not provide adequate mechanical ventilation to remove flammable vapors and mists from the spray paint operation in the spray area.  Employees were spraying in an area with no mechanical ventilation, they were instructed to open the two overhead doors to create a cross-breeze.
Recent events (3)
  • · J (S) $0
  • · C (S) $6236
  • · Z (S) $6236

1910.107 F04

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.107(f)(4): Portable extinguishers. An adequate supply of suitable portable fire extinguishers shall be installed near all spraying areas.   a.) On or about July 6, 2016 the employer did not ensure that portable fire extinguishers were installed near the spraying area.  Employees were spraying in a pole barn that was not equipped with fire suppression and no portable fire extinguishers were available in the area.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.107 G02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:   a.) On or about July 6, 2016, the employer failed to ensure that spraying areas were free of the accumulation of combustible residue. Overspray was visible on the walls, floor and electrical outlets in the spray area. Employees were exposed to hazards from fire and explosion from the potential ignition of the combustible material.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.134 D01 III

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2016
Abate by
Oct 21, 2016
Penalty
Initial $6,236 · Current $6,236

Hazardous substances 227024402592

29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:    a.) On or about July 6, 2016, the employer failed to evaluate the workplace for exposures to airborne contaminants. Employees were exposed to hazards from organic vapors and metals such as, but not limited to, titanium dioxide, am-xylene and stoddard solvent.
Recent events (3)
  • · J (S) $6236
  • · C (S) $6236
  • · Z (S) $6236

1910.134 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2016
Abate by
Oct 21, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 227024402592

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    a.) On or about July 6, 2016, the employer failed to provide employees who were required to wear tight-fitting half mask respirators with medical evaluations to determine if the employee was fit to wear a respirator.  Employees are required to wear the respirators when spray painting in the spray area/pole barn.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.134 F01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2016
Abate by
Oct 21, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 227024402592

29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):     a.) On or about July 6, 2016, the employer failed to ensure employees who were required to wear tight-fitting half mask respirators were fit tested to determine if the respirator seal was adequate.  Employees were exposed to hazards from organic vapors and metals such as, but not limited to titanium dioxide, m-xylene and stoddard solvent during painting operations.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.134 K

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2016
Abate by
Oct 21, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 227024402592

29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:  a.) On or about July 6, 2016, the employer failed to provide training on the necessity of a respirator, how to recognize the limitations and capabilities of a respirator, and how to inspect and maintain a respirator to employees who were required to wear half mask tight-fitting respirators while painting.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

View Quality Welding & Fabrication, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341601664.