PELL CITY, AL —
OSHA Inspection: EISSMANN AUTOMOTIVE NORTH AMERICA, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EISSMANN AUTOMOTIVE NORTH AMERICA, INC in 599 ED GARDNER DRIVE, PELL CITY, AL 35125 (NAICS 336360). OSHA activity number 341709186.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EISSMANN AUTOMOTIVE NORTH AMERICA, INC
- Site address
- 599 ED GARDNER DRIVE
- City
- PELL CITY
- State
- AL
- ZIP
- 35125
- Mailing
- 599 ED GARDNER DRIVE, PELL CITY, AL 35125
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336360
- Employees
- 780
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C07 I
- Issued
- Nov 9, 2016
- Abate by
- Jul 31, 2017
- Penalty
- Initial $12,471 · Current $8,700 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) On or about 8/18/2016 - at 599 Ed Gardener Dr., Pell City, AL, the employer did not provide training to ensure that all employees were aware of and understood the Lockout/Tagout program when employees were working with equipment such as but not limited to conveyors, presses, ovens, and elevators .
Recent events (3)
- — J (S) $8700
- — C (S) $12471
- — Z (S) $12471
1910.212 A03 II
- Issued
- Nov 9, 2016
- Abate by
- Jul 31, 2017
- Penalty
- Initial $10,689 · Current $7,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) On or about 6/13/2016 - in the Cutting Department, the guard on the Eastman Cardinal Round Knife Machine Class 548 was not properly positioned to prevent an employee from being cut by the blade while reaching and pulling the material to the cutting position. (b) On or about 7/29/2016 - in the Cutting Department, the guard on the Eastman Cardinal Round Knife Machine Class 548 was not properly positioned to prevent an employee from being cut by the blade while reaching and pulling the material to the cutting position.
Recent events (3)
- — J (S) $7500
- — C (S) $10689
- — Z (S) $10689
1910.215 A04
- Issued
- Nov 9, 2016
- Abate by
- Jul 31, 2017
- Penalty
- Initial $7,126 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch: (a) On or about 8/30/2016, in the Maintenance Shop, the distance between the work rest and the grinding wheel at the DeWalt bench grinder measured approximately one-quarter to one-half of an inch on the left side.
Recent events (3)
- — J (S) $5000
- — C (S) $7126
- — Z (S) $7126
1910.147 C06 II
- Issued
- Nov 9, 2016
- Abate by
- Jul 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) On or about 8/18/2016 - at 599 Ed Gardener Dr., Pell City, AL, the employer did not certify that periodic inspections of the energy control procedures had been performed for employees servicing and maintaining equipment such as but not limited to conveyors, presses, ovens, and elevators.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Nov 9, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) On or about 8/30/2016 - at the W251 SP Membrane Press LH, a surge protector (relocatable power tap) and was not used in accordance with instructions to power heat lamps.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1910.305 G02 II
- Issued
- Nov 9, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: (a) On or about 8/30/2016 - at the W251 SP Membrane Press RH, a splitter tap was used with a flexible cord to power heat lamps.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Eissmann Automotive North America, INC
View Eissmann Automotive North America, INC's full OSHA safety record →
More inspections in this industry (NAICS 336360)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341709186.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.