PELL CITY, AL —
OSHA Inspection: EISSMANN AUTOMOTIVE NORTH AMERICA, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of EISSMANN AUTOMOTIVE NORTH AMERICA, INC in 599 ED GARDNER DRIVE, PELL CITY, AL 35125 (NAICS 336360). OSHA activity number 341742567.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EISSMANN AUTOMOTIVE NORTH AMERICA, INC
- Site address
- 599 ED GARDNER DRIVE
- City
- PELL CITY
- State
- AL
- ZIP
- 35125
- Mailing
- 599 ED GARDNER DRIVE, PELL CITY, AL 35125
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336360
- Employees
- 780
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- Nov 9, 2016
- Abate by
- Jul 31, 2017
- Penalty
- Initial $12,471 · Current $8,700 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) On or about 8/30/2016 - at Corvette Cell 2, the energy control procedures for the Drying Oven, Spray Booth, Press, and Cooling Unit failed to clearly identify the scope and intended use of the procedure; all of the specific steps to be followed by employees for shutting down, isolating, blocking and securing equipment to control hazardous energy; and specific requirements for testing equipment to verify the effectiveness of lockout devices or other energy control measures.
Recent events (3)
- — J (S) $8700
- — C (S) $12471
- — Z (S) $12471
1910.147 D
- Issued
- Nov 9, 2016
- Abate by
- Jul 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) On or about 8/30/2016 - at Corvette Cell 2, the energy control procedure for the Drying Oven did not cover the required actions when employees are testing or positioning the light curtains and conveyor belt sensors inside the Drying Oven in that the procedure does not address relieving stored energy such as but not limited to pneumatic energy and verifying isolation and deenergization has been accomplished.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 F01
- Issued
- Nov 9, 2016
- Abate by
- Jul 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(1): The sequence of actions required by 29 CFR 1910.147(f)(1) when testing or positioning of machines, where temporary removal of lockout or tagout devices from the energy isolating device is required, were not followed. (a) On or about 8/30/2016 - at Corvette Cell 2, employees are not following the required sequence of actions to test or position the light curtains and conveyor belt sensors inside the Drying Oven.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Nov 9, 2016
- Abate by
- Jul 31, 2017
- Penalty
- Initial $12,471 · Current $8,700 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) On or about 8/30/2016 - at Corvette Cell 2, the employer did not conduct a periodic inspection of the energy control procedures for the Drying Oven, Spray Booth, Press, and Cooling Unit at least annually to ensure that deviations were corrected and inadequacies were identified.
Recent events (3)
- — J (S) $8700
- — C (S) $12471
- — Z (S) $12471
More inspections at Eissmann Automotive North America, INC
View Eissmann Automotive North America, INC's full OSHA safety record →
More inspections in this industry (NAICS 336360)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341742567.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.