Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SMART CONTRACTORS INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SMART CONTRACTORS INC in 56 COOK DR SE, WASHINGTON, DC 20011 (NAICS 236115). OSHA activity number 342072246.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Smart Contractors INC — free Get an email when a new federal OSHA severe-injury report for Smart Contractors INC is published. One employer, no account, unsubscribe in one click.
Site address
56 COOK DR SE
City
WASHINGTON
State
DC
ZIP
20011
Mailing
962 HADDONFIELD RD SUITE 171, CHERRY HILL, NJ 08003
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
6
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 17, 2017
Abate by
Mar 23, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) Front Left Center - Employee was standing on the top plate of the first level wood stud wall frame taking measurements. The employee was not protected from falling approximately 8 feet to the plywood sub-floor below, on or about 1/31/2017.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3803

View Smart Contractors INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342072246.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.