Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRAD MCDONALD ROOFING & CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRAD MCDONALD ROOFING & CONSTRUCTION, INC. in 3965 ALDEA WAY, WESLEY CHAPEL, FL 33544 (NAICS 238160). OSHA activity number 342075546.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brad Mcdonald Roofing & Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Brad Mcdonald Roofing & Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3965 ALDEA WAY
City
WESLEY CHAPEL
State
FL
ZIP
33544
Mailing
11931 BRUIN DRIVE, NEW PORT RICHEY, FL 34654
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
May 3, 2017
Penalty
Initial $6,972 · Current $3,486 Reduced
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.       a) front of house - employees were exposed to a fall of 11 feet 4 inches while using a straight ladder to access the roof. The ladder only extended about one foot above the landing, on or about 2/2/17.
Recent events (2)
  • — I (S) $3486
  • — Z (S) $6972

1926.501 B13

Repeat Gravity 10 2 instances 4 exposed
Issued
May 3, 2017
Penalty
Initial $48,799 · Current $24,400 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):       a)  roof - employees were exposed to a fall of 22 feet while installing a roof on a 5 in 12 pitched roof, in that, fall protection was not used, on or about 2/2/17.    b) lower roof - an employee was exposed to a fall of 11 feet 4 inches while installing a roof on a 3 in 12 pitched roof, in that, fall protection was not used, on or about 2/2/17.      Brad McDonald Roofing & Construction, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1004881, citation number 1, item number 1 and was affirmed as a final order on 12/11/2014, with respect to a workplace located at 7053 Peregrina Loop, Wesley Chapel, FL, 33545.    Brad McDonald Roofing & Construction, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(11), which was contained in OSHA inspection number 997669, citation number 1, item number 1 and was affirmed as a final order on 11/25/2014, with respect to a workplace located at 206 S Moody Ave, Tampa FL 33609.    Brad McDonald Roofing & Construction, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1004881, citation number 2, item number 1 and was affirmed as a final order on 5/21/2015, with respect to a workplace located at 4347 Vermillion Sky Drive, Wesley Chapel, FL 34554.
Recent events (2)
  • — I (R) $24399.5
  • — Z (R) $48799

1926.503 A01

Other-than-serious 1 instance 1 exposed
Issued
May 3, 2017
Abate by
Jun 20, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) roof - an employee was exposed to a fall of 20 feet while installing shingles and was not provided with fall protection training, on or about 2/2/17.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Brad Mcdonald Roofing & Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342075546.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.