Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRE-CON CONSTRUCTION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRE-CON CONSTRUCTION, INC. in 1655 PRUDENTIAL DR, JACKSONVILLE, FL 32207 (NAICS 238120). OSHA activity number 342119401.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pre-Con Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Pre-Con Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1655 PRUDENTIAL DR
City
JACKSONVILLE
State
FL
ZIP
32207
Mailing
1120 E. OLEANDER ST, LAKELAND, FL 33801
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
11
Ownership type
A

5 citations on file for this inspection.

1926.501 B12

Other-than-serious 2 instances 3 exposed
Issued
Apr 4, 2017
Penalty
Initial $8,873 · Current $8,873
29 CFR 1926.501(b)(12): Each employee engaged in the erection of precast concrete members (including, but not limited to the erection of wall panels, columns, beams, and floor and roof "tees") and related operations such as grouting of precast concrete members, who is 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems:    a.  On or about February 16, 2017, at the sixth level of the garage building, two employees installing and securing precast double-T beams were not protected from a 62 feet fall hazard from the edge and 11 feet fall hazards from the inside by the use of a fall protection system.    b.  On or about February 16, 2017, at the fifth level of the garage building, one employee grabbing welding leads and doing welding work was not protected from a 51 feet fall hazard from the edge by the use of a fall protection system.
Recent events (3)
  • — F (O) $8873
  • — C (S) $8873
  • — Z (S) $8873

1926.502 G01 II

Other-than-serious 1 instance 1 exposed
Issued
Apr 4, 2017
Penalty
Initial $8,873 · Current $0 Reduced
29 CFR 1926.502(g)(1)(ii): When erecting precast concrete members, the control lines were not erected at least 6 (1.8m) nor more than 60 feet (18m) or half the length of the member being erected, whichever is less, from the leading edge:    a.  On or about February 16, 2017, at the fifth level of the garage building, the warning line erected by the employer was less than 6 feet from the leading edge, exposing employees to a 51 feet fall hazard.
Recent events (3)
  • — F (O) $0
  • — C (S) $8873
  • — Z (S) $8873

1926.502 G03 I

Other-than-serious 1 instance 3 exposed
Issued
Apr 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.502(g)(3)(i): Each line was not flagged or otherwise clearly marked at not more than 6-foot intervals with high visibility material:    a.  On or about February 16, 2017, at the north fifth level side of the garage building, the warning line erected by the employer was not flagged with high visibility material at least in 6 foot intervals, exposing employees to a 51 feet fall hazard.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.502 G03 II

Other-than-serious 1 instance 3 exposed
Issued
Apr 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.502(g)(3)(ii): Each line was not rigged and supported in such a way that its lowest point is not less than 39 inches from the walking/working surface:    a. On or about February 16, 2017, at the south fifth level side of the garage building, the warning line erected by the employer was rigged less than 39 inches from the walking/working surface, exposing employees to a 51 feet fall hazard.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.1053 B04

Serious Gravity 5 3 instances 2 exposed
Issued
Apr 4, 2017
Penalty
Initial $6,338 · Current $3,169 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    a. On or about February 16, 2017, at the north fifth level of the building, one employee climbed on a closed 8-foot Werner stepladder against the wall to do work.        b. On or about February 16, 2017, at the north fifth level of the building, one employee climbed on a closed 6-foot Werner stepladder against the wall to do welding work.          c. On or about February 16, 2017, at the south fifth level of the building, one employee climbed on a closed 8-foot Werner stepladder against the concrete beam to do work.
Recent events (3)
  • — F (S) $3169
  • — C (S) $6338
  • — Z (S) $6338

View Pre-Con Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342119401.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.