MORAINE, OH ·
OSHA Inspection: FUYAO GLASS AMERICA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FUYAO GLASS AMERICA, INC. in 2801 WEST STROOP ROAD, MORAINE, OH 45439 (NAICS 327215). OSHA activity number 342133501.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FUYAO GLASS AMERICA, INC.
- Site address
- 2801 WEST STROOP ROAD
- City
- MORAINE
- State
- OH
- ZIP
- 45439
- Mailing
- 2801 WEST STROOP ROAD, MORAINE, OH 45439
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327215
- Employees
- 1800
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.22 C
- Issued
- Jun 12, 2017
- Abate by
- Jun 29, 2017
- Penalty
- Initial $5,975 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(c): (c) Access and egress. The employer must provide, and ensure each employee uses, a safe means of access and egress to and from walking-working surfaces. On February 11, 2017, at FBT 1, a furnace operator was exposed to a fall hazard while trying to climb over a 3ft. high furnace without any safe means of access and egress from the floor to inside the furnace.
Recent events (3)
- · F (S) $0
- · C (S) $5975
- · Z (S) $5975
1910.146 C01
- Issued
- Jun 12, 2017
- Abate by
- Jul 14, 2017
- Penalty
- Initial $9,959 · Current $0 Reduced
General-duty citation text
29 CFR 1910.146(c)(1): The employer shall evaluate the workplace to determine if any spaces are permit-required confined spaces. NOTE: Proper application of the decision flow chart in Appendix A to section 1910.146 would facilitate compliance with this requirement. The employer had not evaluated the furnaces to determine that they were permit-required confined spaces.
Recent events (3)
- · F (O) $0
- · C (S) $9959
- · Z (S) $9959
1910.146 G01
- Issued
- Jun 12, 2017
- Abate by
- Jul 28, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(g)(1): The employer shall provide training so that all employees whose work is regulated by this section acquire the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this section. The employer had not ensured that employees entering the furnaces (FBT) to perform work had not received training on permit-required confined spaces in a language necessary to acquire the understanding, knowledge and skills for safe performance.
Recent events (3)
- · F (O) $0
- · C (S) $0
- · Z (S) $0
1910.147 D
- Issued
- Jun 12, 2017
- Abate by
- Jul 14, 2017
- Penalty
- Initial $9,959 · Current $5,500 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: Employees who performed servicing and maintenance on the Furnaces were not required to: (1) affix lockout devices to the electrical energy source. (2) prior to starting work on machines that have been locked out, verify that isolation and deenergization of the furnace had been accomplished. a. During the daily changeover and replacement of rollers in the Glass Bending Area, furnace operators are exposed to a struck-by, caught in-between hazard from the drop of the rollers. b. On February 11, 2017, while changing heating elements in FBT 1, Furnace, employees who entered the furnace to install the heating elements did not lockout the furnace and verify that the electrical power was shut off to the furnace before starting work.
Recent events (3)
- · F (S) $5500
- · C (S) $9959
- · Z (S) $9959
1910.212 A01
- Issued
- Jun 12, 2017
- Penalty
- Initial $11,950 · Current $6,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. In the EPBL 2 Print Room, a Print Operator was exposed to a struck-by, caught in-between hazard from the squeege and bar on the print table when it moves across the screen during operation and during inking and cleaning of the screen due to the lack of a safeguard to protect the operator.
Recent events (3)
- · F (S) $6500
- · C (S) $11950
- · Z (S) $11950
More inspections at Fuyao Glass America, INC.
View Fuyao Glass America, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327215)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342133501.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.