OSHA Inspection: FUYAO GLASS AMERICA, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FUYAO GLASS AMERICA, INC. in 2801 WEST STROOP ROAD, MORAINE, OH 45439 (NAICS 327215). OSHA activity number 342139953.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fuyao Glass America, INC. for free Get an email when a new federal OSHA severe-injury report for Fuyao Glass America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2801 WEST STROOP ROAD
City
MORAINE
State
OH
ZIP
45439
Mailing
2801 WEST STROOP ROAD, MORAINE, OH 45439
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327215
Employees
1800
Ownership type
Private (A)

2 citations on file for this inspection.

1904.29 B01

Other-than-serious 1 instance 1800 exposed
Issued
Jun 12, 2017
Abate by
Jun 22, 2017
Penalty
Initial $1,992 · Current $1,992
29 CFR 1904.29(b)(1): What do I need to do to complete the OSHA 300 Log? You must enter information about your business at the top of the OSHA 300 Log, enter a one or two line description for each recordable injury or illness, and summarize this information on the OSHA 300-A at the end of the year.  a)  Since February 2017 there were 3 recordable injuries on the OSHA 300 log with no description of the injury entered in column F.
Recent events (1)
  • · Z (O) $1992

1910.134 E06 I

Other-than-serious 1 instance 2 exposed
Issued
Jun 12, 2017
Abate by
Jun 29, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 1073

29 CFR 1910.134(e)(6)(i): The employer did not obtain from the physician or other licensed health care professional (PLHCP)  a written recommendation regarding the employee's ability to use the respirator:  (a) The employer did not have a recommendation from the licensed health care professional for all employees required to wear powered air purifying respirators in the encapsulation PVC department.
Recent events (1)
  • · Z (O) $0

View Fuyao Glass America, INC.'s full OSHA safety record →