FRIANT, CA —
OSHA Inspection: TABLE MOUNTAIN CASINO
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TABLE MOUNTAIN CASINO in 8184 TABLE MOUNTAIN ROAD, FRIANT, CA 93626 (NAICS 713210). OSHA activity number 342179843.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TABLE MOUNTAIN CASINO
- Site address
- 8184 TABLE MOUNTAIN ROAD
- City
- FRIANT
- State
- CA
- ZIP
- 93626
- Mailing
- PO BOX 445, FRIANT, CA 93626
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713210
- Employees
- 976
- Ownership type
- A
Citations
23 citations on file for this inspection.
1910.22 A02
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $5,432 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition. When wet processes are used, drainage must be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats must be provided: Dish Washing and Bakery Areas: Employees were not protected from slick and slippery floors where water mixed with grease is spilled on the floors routinely and they were exposed to slips and falls.
Recent events (2)
- — I (S) $0
- — Z (S) $5432
1910.22 D01
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): Walking-working surfaces were not inspected, regularly and as necessary, and maintained in a safe condition: Dish Washing and Bakery Areas: The work room floor was not inspected regularly to ensure floor were day and kept free from potential slip and fall related hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 A
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $7,243 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(a): Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. a) Dish Washing Areas: Stewards were not provided appropriate gloves such as nitrile gloves to prevent skin irritation hazards while handling Aqua Dry, Aqua Clean and Oven Jell. Stewards used synthetic vinyl gloves and were exposed to skin irritation hazards. b) EDR Employee Dining Area: Line cooks were not provided appropriate gloves such as wire mesh gloves to prevent finger amputation hazards while handling knives and meat slicers. Line cooks used synthetic vinyl gloves and were exposed to finger amputation. c) Maintenance Building: Green welding goggles and a welding face shield were not maintained in a sanitary condition.
Recent events (2)
- — I (O) $0
- — Z (S) $7243
1910.132 D01 I
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $7,243 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(d)(1)(i): Select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment; a) Dish Washing Areas: Stewards washing dishes were not required to use appropriate gloves such as nitrile gloves, to protect against the hazards of Aqua Dry, Aqua Clean and Ovenjell materials. Stewards used synthetic vinyl gloves and were exposed to skin irritation hazards. b) EDR Employee Dining Area: Employer did not require cooks to use appropriate gloves such as wire mesh gloves to protect against the hazards of using meat slicers and knives. The cooks used synthetic vinyl gloves and were exposed to finger amputation related injuries.
Recent events (2)
- — I (O) $0
- — Z (S) $7243
1910.138 A
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): General requirements. Employers did not select and require employees to use appropriate hand protection when employees' hands are exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes: a) Dish Washing Areas: Stewards were not provided with nitrile gloves to prevent skin irritation hazards while handling Aqua Dry, Aqua Clean and Oven Jell. Stewards use synthetic vinyl gloves while handling these materials and were exposed to skin irritation hazards. b) EDR Employee Dining Area: Cooks were not provided with mesh gloves to prevent finger amputation hazards while handling knives and meat slicers. Line cooks used synthetic vinyl gloves and were exposed to finger amputation.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C01
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $7,243 · Current $7,243
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. Facility Wide: Energy control procedures (lockout/tag out), periodic audits, and training were not provided. All required elements of an energy control procedures were not understood by employees and that the knowledge and skills required for the safe application, usage and removal of the energy controls were not acquired by employees performing servicing, testing, inspecting, repairing, and maintaining work on a machine or equipment throughout the facility, where the unexpected release of stored energy could occur and cause injury, equipment shall be isolated from the energy source.
Recent events (2)
- — I (S) $7243
- — Z (S) $7243
1910.147 C04 I
- Issued
- Apr 6, 2017
- Abate by
- Aug 1, 2017
- Penalty
- Initial $7,243 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Employer did not ensure that procedures were developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in maintenance activities: Facility Wide: Procedures were not developed, documented and utilized for all electrical equipment and machines when employees engaged in activities, such as troubleshooting, testing, repairing, inspecting, and maintaining a machine or equipment, where the unexpected release of stored energy could occur and cause injury.
Recent events (2)
- — I (S) $0
- — Z (S) $7243
1910.147 C06 I
- Issued
- Apr 6, 2017
- Abate by
- Aug 1, 2017
- Penalty
- Initial $7,243 · Current $7,243
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. Facility Wide: A periodic inspection was not performed to the energy control program (lockout/tagout), on an annual basis, that included a review of documented lockout procedures and authorized employees.
Recent events (2)
- — I (S) $7243
- — Z (S) $7243
1910.147 C07 IV
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training has been accomplished and is being kept up to date. The certification shall contain each employee's name and dates of training. Facility Wide: Training was not certified for all authorized, affected and other personnel on the energy control procedures (lockout/tag out).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 III B
- Issued
- Apr 6, 2017
- Abate by
- Aug 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever a periodic inspections under 29 CFR 1910.147(c)(6) reveled that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: Facility Wide: Energy control training was not provided for electricians. The electrician was performing testing and troubleshooting of an electrical circuit and did not wear appropriate PPE and could not determine means necessary for energy isolation and control when working with live electrical power prior to beginning his work.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Apr 6, 2017
- Penalty
- Initial $4,617 · Current $0 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage did not separate from fuel-gas cylinders, a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. Maintenance Building: Oxygen and fuel gases were stored together inside a yellow metal cage.
Recent events (2)
- — I (O) $0
- — Z (S) $4617
1910.303 B01
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $5,432 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Examination. Electric equipment was not free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations: EDR Employee Dining Kitchen: A wall mounted electrical panel door cam lock was missing to prevent unintentional opening of the door and workers were exposed to electrical shock hazard.
Recent events (2)
- — I (O) $0
- — Z (S) $5432
1910.304 G05
- Issued
- Apr 6, 2017
- Penalty
- Initial $4,617 · Current $4,617
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective. Warehouse: One orange temporary flexible cord, approximately 50 foot, was not provided with a grounding pin. The pin was broken off from male plug. The plug was plugged into a wall mounted receptacle to supply 120 volts to Junghieinrich electric hand pallet truck. Employees were exposed to electrical shock hazard.
Recent events (2)
- — I (S) $4617
- — Z (S) $4617
1910.305 G01 IV A
- Issued
- Apr 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: Warehouse: One orange temporary flexible cord, approximately 50 foot long, was used as a substitute for fixing wiring. The cord was not designed to be used as a permanent wiring. The cord was plugged into a wall mounted receptacle to supply 120 volts to Junghieinrich electric hand pallet truck. Employees were exposed to electrical shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 A02
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $7,243 · Current $0 Reduced
General-duty citation text
29 CFR 1910.333(a)(2): "Where exposed live parts were not de-energized, other safety related work practices were not used to protect employees who could be exposed to the electrical hazards involved: Facility Wide: The electricians who perform electrical repair, test, inspect, troubleshoot, and service on various machines and equipment, did not use safety related work practices to protect them from the exposure to the electrical shock and arc/blast hazards when exposed to 120 and 208 volts.
Recent events (2)
- — I (S) $0
- — Z (S) $7243
1910.335 A01 I
- Issued
- Apr 6, 2017
- Abate by
- Aug 1, 2017
- Penalty
- Initial $7,243 · Current $7,243
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards were not provided with, and did not use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed: Facility Wide: The electricians were working on live electrical parts while performing repair, test, inspect, troubleshoot, and service work on various electrical machines and equipment. They were exposed to voltage of 120 and 208 and were not provided with appropriate electrical protective equipment, such as voltage rated gloves, leather protectors, flame resistant clothing, arc rated face shield balaclava and/or an arc rated hood.
Recent events (2)
- — I (S) $7243
- — Z (S) $7243
1910.335 A01 V
- Issued
- Apr 6, 2017
- Abate by
- Aug 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(v): Employees exposed to the danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion did not wear protective equipment for the eyes or face: Facility Wide: The electricians performing repair, test, inspect, troubleshoot, and service work on various electrical machines and equipment on live electrical parts were not wearing an adequate rated arc rated face shield to protect their head, face, and neck.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.335 A02 I
- Issued
- Apr 6, 2017
- Abate by
- Aug 1, 2017
- Penalty
- Initial $7,243 · Current $0 Reduced
General-duty citation text
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts. Facility Wide: The employer did not provide insulated tools and equipment for the electricians who worked on and near live energized parts, conductors, and equipment while performing repair, test, inspect, troubleshoot, and maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $7243
1910.335 B01
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $5,432 · Current $0 Reduced
General-duty citation text
29 CFR 1910.335(b)(1): Safety signs and tags. Safety signs, safety symbols, or accident prevention tags were not used where necessary to warn employees about electrical hazards which may endanger them, as required by 1910.145: Facility Wide: Safety signs, safety symbols or accident prevention tags were not installed on the outside covers of the premises wiring such electrical power panels, safety switches and control panels to warn employees about electrical hazards when they were required to perform repair, test, inspect, troubleshoot, and maintenance while the machines and equipment were energized.
Recent events (2)
- — I (O) $0
- — Z (S) $5432
1910.1200 G08
- Issued
- Apr 6, 2017
- Penalty
- Initial $4,617 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.) Dish Washing, EDR Employee Dining and Maintenance Areas: Safety Data Sheets (SDS) were not available for irritative aqua dry, aqua clean, oven jell, and flammable lacquer thinner, paint thinner, denatured alcohol, and acetone.
Recent events (2)
- — I (O) $0
- — Z (S) $4617
1910.1200 H01
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets: Dish Washing, EDR Employee Dining and Maintenance Areas: Information and training of the hazardous irritative and flammable chemicals was not provided.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.1030 F05
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $5,432 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1030(f)(5): Healthcare Professional's Written Opinion. The employer did not obtain and provide the employee with a copy of the evaluating healthcare professional's written opinion within 15 days of the completion of the evaluation. Facility Wide: A post-exposure medical evaluation from a healthcare professional was not provided to three (3)employees injured from needle stick to finger in calendar year 2016.
Recent events (2)
- — I (S) $0
- — Z (S) $5432
1904.39 A02
- Issued
- Apr 6, 2017
- Penalty
- Initial $1,000 · Current $1,000
General-duty citation text
29 CFR 1904.39(a)(2): Basic Requirement. Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA. Facility Wide: Employer failed to report an in-patient hospitalization of a burn related injury occurring within 24 hours of a work related incident. On February 11, 2017, around 6:50 pm, an employee carrying corrosive material spill on his pants while performing his duties at Table Mountain Casino. The incident was reported to OSHA on February 15, 2107, at 2:50 pm.
Recent events (2)
- — I (O) $1000
- — Z (O) $1000
More inspections at Table Mountain Casino
View Table Mountain Casino's full OSHA safety record →
More inspections in this industry (NAICS 713210)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342179843.