COLCHESTER, CT —
OSHA Inspection: EAGLE MANUFACTURING COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EAGLE MANUFACTURING COMPANY, INC. in 13 HOMONICK ROAD, COLCHESTER, CT 06415 (NAICS 331210). OSHA activity number 342205408.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAGLE MANUFACTURING COMPANY, INC.
- Site address
- 13 HOMONICK ROAD
- City
- COLCHESTER
- State
- CT
- ZIP
- 06415
- Mailing
- P.O. BOX 186, COLCHESTER, CT 06415
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331210
- Employees
- 21
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.37 B02
- Issued
- Apr 26, 2017
- Abate by
- Jun 13, 2017
- Penalty
- Initial $3,259 · Current $1,955 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": A. On or about April 4, 2017, Shop: The designated side-hinged exterior emergency exit door at the front of the shop, near the 12" pipe threading machine, was not identified and marked by an EXIT sign.
Recent events (2)
- — I (S) $1955.4
- — Z (S) $3259
1910.37 B05
- Issued
- Apr 26, 2017
- Abate by
- Jun 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): A. On or about April 4, 2017, the door from the shop to the office area was not identified as "NOT AN EXIT" or with a sign indicating its actual use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B06
- Issued
- Apr 26, 2017
- Abate by
- Jun 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: A. On or about April 4, 2017, Shop: A discolored paper EXIT sign at the rear emergency exit door was not illuminated.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 I
- Issued
- Apr 26, 2017
- Abate by
- Jul 26, 2017
- Penalty
- Initial $3,259 · Current $1,955 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): The employer did not determine if the voluntary use of a respirator did not in itself create a hazard: A. On or about April 4, 2017, Grinding Area: The employer allowed an employee to voluntarily wear a Honeywell 5500-30M tight-fitting half-mask elastomeric respirator fitted with organic vapor cartridges while engaged in grinding operations. The employer did not ensure that the respirator itself did not cause a hazard.
Recent events (2)
- — I (S) $1955.4
- — Z (S) $3259
1910.134 C02 II
- Issued
- Apr 26, 2017
- Abate by
- Jul 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: A. On or about April 4, 2017, Shop: The company had not implemented parts of a written respiratory protection program to address medical evaluation or cleaning and storage of respirators used on a voluntary basis, including Honeywell 5500-300M tight-fitting half-mask elastomeric respirator with organic vapor cartridges and 3M N95 filtering facepiece respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K06
- Issued
- Apr 26, 2017
- Abate by
- Jul 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: A. On or about April 4, 2017, Shop: Where employees engaged in grinding operations wore 3M N95 filtering facepiece respirators on a voluntary basis, the employer did not document that the basic advisory information included in Appendix D had been provided.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Apr 26, 2017
- Abate by
- Aug 25, 2017
- Penalty
- Initial $4,563 · Current $2,738 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: A. On or about April 4, 2017, Shop: The employer's lockout/tagout program was generic in nature and did not include machine specific lockout procedures; periodic inspections; or documented training for authorized, affected and other employees. Shop equipment included pipe threading machine, Marvel horizontal and vertical band saws, Piranha press brake, and a Peddinghaus punch press, among others, where hazardous energy sources would not be under the express control of one performing maintenance.
Recent events (2)
- — I (S) $2737.8
- — Z (S) $4563
1910.212 A03 II
- Issued
- Apr 26, 2017
- Abate by
- Jun 13, 2017
- Penalty
- Initial $4,563 · Current $2,738 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): A. On or about April 4, 2017, Shop: At the Marvel Series 13A horizontal metal-cutting band saw, a 5 1/2-inch section of the unused portion of the blade was unguarded. The unguarded blade was to the left of the point of operation, adjacent to the operator's station.
Recent events (2)
- — I (S) $2737.8
- — Z (S) $4563
1910.304 G06 VI C 8
- Issued
- Apr 26, 2017
- Abate by
- Jun 13, 2017
- Penalty
- Initial $3,259 · Current $1,955 Reduced
General-duty citation text
29 CFR 1910.304(g)(6)(vi)(C)(8): Exposed noncurrent-carrying metal parts of portable hand lamp that may become energized was not grounded: A. On or about April 4, 2017, Shop: At the Peddinghaus punch press, a 2-wire metal-encased clip-on work lamp was not grounded.
Recent events (2)
- — I (S) $1955.4
- — Z (S) $3259
1910.305 G01 IV A
- Issued
- Apr 26, 2017
- Abate by
- Jun 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: A. On or about April 4, 2017, in the following locations, flexible cords were used in lieu of the fixed wiring of the building: 1. Grinding Room: An orange flexible cord fitted with a two outlet 110V receptacle box was used to energize a DeWalt off-hand grinder. 2. Shop, at the Parts Cleaning Station: An orange extension cord plugged into a 6-outlet relocatable power tap which was in turn plugged into a wall outlet energized a Makita off-hand grinder. 3. Shop, at the work table in front of the Enerpac 200 ton press: A yellow extension cord which was plugged into a wall outlet across the room behind the Piranha press brake was used to power a DeWalt off-hand grinder. 4. Front of Shop: A red extension cord, plugged into a wall outlet in the office area, was used to power the Frost Fighter indirect heater, which was used in the shop during the winter.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV C
- Issued
- Apr 26, 2017
- Abate by
- Jun 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows, floors, or similar openings. A. On or about April 4, 2017, Shop: The flexible cordset for the Frost Fighter indirect fired heater used in the shop was plugged into an outlet in the office and was run through the doorway.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Eagle Manufacturing Company, INC.
View Eagle Manufacturing Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331210)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342205408.