OSHA Inspection: THE POINT CASINO

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of THE POINT CASINO in 7989 SALISH LANE NE, KINGSTON, WA 98346 (NAICS 713210). OSHA activity number 342213618.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Point Casino — free Get an email when a new federal OSHA severe-injury report for The Point Casino is published. One employer, no account, unsubscribe in one click.
Establishment
THE POINT CASINO
Site address
7989 SALISH LANE NE
City
KINGSTON
State
WA
ZIP
98346
Mailing
7989 SALISH LANE NE, KINGSTON, WA 98346
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713210
Employees
150
Ownership type
A

8 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
May 10, 2017
Abate by
Jun 27, 2017
Penalty
Initial $6,519 · Current $3,260 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:      A)    In the maintenance shop building, there was an open side to the upper storage loft that did not have a fall protection system in place.
Recent events (2)
  • — I (S) $3259.5
  • — Z (S) $6519

1910.212 B

Serious Gravity 1 1 instance 3 exposed
Issued
May 10, 2017
Penalty
Initial $4,889 · Current $2,445 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    A)    In the maintenance Shop, there was a table top drill press, that was not secured to the table surface.
Recent events (2)
  • — I (S) $2444.5
  • — Z (S) $4889

1910.215 A04

Serious Gravity 5 1 instance 3 exposed
Issued
May 10, 2017
Penalty
Initial $6,519 · Current $3,260 Reduced
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:    A)    In the shop, there was a bench grinder in use that did not have a work rest installed for one of its grinding wheels.
Recent events (2)
  • — I (S) $3259.5
  • — Z (S) $6519

1910.215 B09

Serious Gravity 5 1 instance 3 exposed
Issued
May 10, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  A)     In the maintenance shop, there was a bench grinder that did not have its tongue guards properly installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 B04 II B

Other-than-serious 1 instance 3 exposed
Issued
May 10, 2017
Penalty
Initial $6,519 · Current $0 Reduced
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4:    A) In the shop, a 15 amp relocatable power tap was plugged into a drill press and a bench grinder, with a total current draw of 17 amps.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6519

1910.305 G01 IV B

Serious Gravity 5 1 instance 3 exposed
Issued
May 10, 2017
Penalty
Initial $6,519 · Current $3,260 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:    A)     The loft of the maintenance building, was lit by a string of incandescent lights that were attached to a flexible cord.  The cord was plugged into an outlet in the shop area, and went through several holes to reach the loft.
Recent events (2)
  • — I (S) $3259.5
  • — Z (S) $6519

1910.22 B

Other-than-serious 1 instance 3 exposed
Issued
May 10, 2017
Abate by
Jun 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.22(b): The employer did not ensure that each walking-working surface can support the maximum intended load for that surface.  A) in the maintenance building there was a storage loft that was above an office.  There was no posted load rating for that storage area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.132 D02

Other-than-serious 1 instance 17 exposed
Issued
May 10, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:  A)     The employer did not have a written personal protective equipment assessment for the facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View The Point Casino's full OSHA safety record →