Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CORRY RUBBER CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CORRY RUBBER CORPORATION in 601 W. MAIN STREET, CORRY, PA 16407 (NAICS 325212). OSHA activity number 342439270.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Corry Rubber Corporation — free Get an email when a new federal OSHA severe-injury report for Corry Rubber Corporation is published. One employer, no account, unsubscribe in one click.
Site address
601 W. MAIN STREET
City
CORRY
State
PA
ZIP
16407
Mailing
601 W. MAIN STREET, CORRY, PA 16407
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325212
Employees
35
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 3, 2017
Abate by
Dec 1, 2017
Penalty
Initial $5,387 · Current $2,960 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to:    A.)  Corry Rubber Corporation; Mix Area - On or about 1/3/17, and at times prior thereto, employees were potentially exposed to fire and deflagration hazards from a dust collector located inside.  Dust collectors included, but were not limited to, the Celtron dust collector which was located inside the building and was not equipped with any devices to mitigate a potential dust explosion.  The dust collector collected a combination of dust that included, but was not limited to, carbon black, natural rubber, sulfur, and zinc oxide.    B.)  Corry Rubber Corporation; Mix Area - On or about 1/3/17, and at times prior thereto, employees were potentially exposed to fire and deflagration hazards from a dust collector that was not equipped with devices and systems to prevent the propagation of deflagrations and associated flame fronts from the dust collector through the associated dust collection system duct work.  Celtron dust collector  Model #DSLG-10-8 was not equipped with approved devices to prevent the propagation of a deflagration and associated flame fronts throughout the dust collection system.   The dust collector collected a combination of dust that included, but was not limited to, carbon black, natural rubber, sulfur, and zinc oxide
Recent events (2)
  • — I (S) $2960
  • — Z (S) $5387

1910.303 G01 II

Other-than-serious 1 instance 3 exposed
Issued
Jul 3, 2017
Abate by
Jul 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): Working space required by this standard was  used for storage:    A.)  Corry Rubber Corporation; 405 W. Main Street;  Mixing room - On or about 1/3/17, and at times prior thereto, pallets were being stored underneath 480 volt electrical panels.  The electrical panels serviced items including, but not limited to, the mixer and the dust collector.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Corry Rubber Corporation's full OSHA safety record →