ERIE, PA —
OSHA Inspection: LAKEVIEW FORGE COMPANY, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LAKEVIEW FORGE COMPANY, LLC in 1725 PITTSBURGH AVENUE, ERIE, PA 16505 (NAICS 332111). OSHA activity number 342559671.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LAKEVIEW FORGE COMPANY, LLC
- Site address
- 1725 PITTSBURGH AVENUE
- City
- ERIE
- State
- PA
- ZIP
- 16505
- Mailing
- 1725 PITTSBURGH AVENUE, ERIE, PA 16505
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332111
- Employees
- 24
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Feb 13, 2018
- Abate by
- Mar 12, 2018
- Penalty
- Initial $5,174 · Current $3,622 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Lakeview Forge Company, LLC. On or about August 16, 2017, and times prior thereto, employees performed servicing and maintenance work on machines that included but were not limited mechanical power presses. Specific energy control procedures had not been developed for employees to utilize when performing servicing and maintenance on machines such as, but not limited to, the mechanical power presses.
Recent events (2)
- — I (S) $3621.8
- — Z (S) $5174
1910.147 C06 I
- Issued
- Feb 13, 2018
- Abate by
- Mar 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: a) Lakeview Forge Company, LLC. On or about August 16, 2017, and times prior thereto, employees performed servicing and maintenance work on machines that included but were not limited mechanical power presses. Periodic inspections of the lockout/tagout procedures and program had not been conducted.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 D09 I
- Issued
- Feb 13, 2018
- Abate by
- Mar 12, 2018
- Penalty
- Initial $5,174 · Current $3,622 Reduced
General-duty citation text
29 CFR 1910.217(d)(9)(i): The employer did not establish a diesetting procedure that will insure compliance with paragraph (c) of this section: a) Lakeview Forge Company, LLC. On or about August 16, 2017, die setting procedures for the mechanical power presses were not established.
Recent events (2)
- — I (S) $3621.8
- — Z (S) $5174
1910.217 D09 IV
- Issued
- Feb 13, 2018
- Abate by
- Mar 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(d)(9)(iv): The employer did not provide and enforce the use of safety blocks for use whenever dies are being adjusted or repaired in the press: a) Lakeview Forge Company, LLC. On or about August 16, 2017, safety blocks were not used on the mechanical power presses during die changes and/ or adjustments.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 C03 IV D
- Issued
- Feb 13, 2018
- Abate by
- Mar 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(c)(3)(iv)(d): Records of inspections and maintenance of each pull-out device were not kept in accordance with paragraph (e) of this section: a) Lakeview Forge Company, LLC. On or about August 16, 2017, employees used pull-out devices to keep hands out of the point of operation when operating mechanical power presses. Current records of inspections of the pull-out devices were not maintained.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.217 E01 I C
- Issued
- Feb 13, 2018
- Abate by
- Mar 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(e)(1)(i)(C): The employer did not maintain a certification record of each inspection, and maintenance task performed, under the general component of the inspection program that includes the date of the maintenance task, the signature of the person who performed the maintenance task, and the serial number, or other identifier, of the power press maintained: a) Lakeview Forge Company, LLC. On or about August 16, 2017, current records of mechanical power press inspections, and maintenance and repair tasks performed, were not maintained.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Lakeview Forge Company, LLC
View Lakeview Forge Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332111)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342559671.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.