Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTERLAKE MECALUX, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of INTERLAKE MECALUX, INC. in 701 INTERLAKE DRIVE, PONTIAC, IL 61764 (NAICS 337215). OSHA activity number 342604410.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Interlake Mecalux, INC. — free Get an email when a new federal OSHA severe-injury report for Interlake Mecalux, INC. is published. One employer, no account, unsubscribe in one click.
Site address
701 INTERLAKE DRIVE
City
PONTIAC
State
IL
ZIP
61764
Mailing
701 INTERLAKE DRIVE, PONTIAC, IL 61764
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Case closed
Last modified
Data loaded
NAICS code
337215
Employees
240
Ownership type
A

7 citations on file for this inspection.

1910.134 C01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Feb 20, 2018
Penalty
Initial $6,911 · Current $0 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  On or about August 31, 2017, employees engaged in powder coating activities were required to wear a Honeywell Type C loose fitting supplied air hood respirator or a 95N disposable respirator to operate in the area and the employer did not have in place a written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures established and implemented for the required respirator use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6911

1910.134 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Mar 16, 2018
Penalty
Initial $0 · Current $3,800
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Note:  The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.      On or about August 31, 2017, employees engaged in powder coating activities were required to wear a Honeywell Type C loose fitting supplied air hood respirator or a 95N disposable respirator to operate in the area and the employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace
Recent events (2)
  • — I (S) $3800
  • — Z (S) $0

1910.134 D01 III

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:    On or about August 31, 2017, employees engaged in powder coating activities were required to wear a supplied air respirator or a 95N disposable respirator to operate in the area and the employer did not assess the respiratory hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Feb 20, 2018
Penalty
Initial $9,239 · Current $0 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   On or about August 31, 2017, employees engaged in powder coating activities used material with potential to cause cancer, skin sensitization and combustible dust, among other, and the employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii).
Recent events (2)
  • — I (S) $0
  • — Z (S) $9239

1910.1200 H03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $5,100
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area:    On or about August 31, 2017, employees engaged in powder coating activities used material with potential to cause cancer, skin sensitization and combustible dust, among other, and the employer did not provide employee training that included the physical and health hazards of the powder coating materials.
Recent events (2)
  • — I (S) $5100
  • — Z (S) $0

1910.1200 H03 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer:  On or about August 31, 2017, employees engaged in powder coating activities used material with potential to cause cancer, skin sensitization and combustible dust, among other, and the employer did not provide employee training that included an explanation of Signal word(s), Hazard statement(s), Pictogram(s), and Precautionary statement(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Other-than-serious 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:    On or about August 31, 2017, employees engaged in powder coating activities were required to wear a 95N disposable respirator to operate in the area and the employer did not provide a fit test to determine the employee's ability to use a respirator prior to initial use of the respirator.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Interlake Mecalux, INC.'s full OSHA safety record →