Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RRC HOME IMPROVEMENT, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RRC HOME IMPROVEMENT, INC. in 15 KENILWORTH DR, SHORT HILLS, NJ 07078 (NAICS 238350). OSHA activity number 342785516.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RRC Home Improvement, INC. — free Get an email when a new federal OSHA severe-injury report for RRC Home Improvement, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15 KENILWORTH DR
City
SHORT HILLS
State
NJ
ZIP
07078
Mailing
51 GARDEN STREET APT #2, NEWARK, NJ 07105
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.1053 B07

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 8, 2017
Penalty
Initial $2,988 · Current $2,988
29 CFR 1926.1053(b)(7): Ladders shall not be used on slippery surfaces unless secured or provided with slip-resistant feet to prevent accidental displacement. Slip-resistant feet shall not be used as a substitute for care in placing, lashing, or holding a ladder that is used upon slippery surfaces including, but not limited to, flat metal or concrete surfaces that are constructed so they cannot be prevented from becoming slippery.  (a) Rear/Deck of residential home- The ladder an employee was using was not secured to prevent accidental displacement; on or about 11/18/17.
Recent events (1)
  • — Z (S) $2988

1926.501 B13

Repeat Gravity 10 1 instance 1 exposed
Issued
Dec 8, 2017
Penalty
Initial $20,914 · Current $20,914
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  a) Residential front entrance canopy- Employee working on the roof was not using a fall protection system and was exposed to a fall of approximately 18 feet onto the ground below; on or about 11/20/17.  2nd Repeat:  RRC Home Improvement, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13) which was contained in OSHA inspection number 807821, citation number 2, item number 1 and was affirmed as a final order on 05/22/2014, with respect to a workplace located at 122 Newman Avenue, Bayonne, NJ 07002.
Recent events (1)
  • — Z (R) $20914

1926.1053 B01

Repeat Gravity 5 1 instance 1 exposed
Issued
Dec 8, 2017
Penalty
Initial $14,939 · Current $14,939
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access;  a) Residential front entrance canopy- Employee was accessing a ladder that did not extend 3 feet over the landing; on or about 11/20/17.  2nd Repeat: RRC Home Improvement, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.1053(b)(1) which was contained in OSHA inspection number 807821, citation number 2, item number 3 and was affirmed as a final order on 05/22/2014, with respect to a workplace located at 122 Newman Avenue, Bayonne, NJ 07002.
Recent events (1)
  • — Z (R) $14939

View RRC Home Improvement, INC.'s full OSHA safety record →