LODI, NJ —
OSHA Inspection: RRC HOME IMPROVEMENT, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RRC HOME IMPROVEMENT, INC. in 313 ROUTE 46, LODI, NJ 07644 (NAICS 238350). OSHA activity number 347600652.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RRC HOME IMPROVEMENT, INC.
- Site address
- 313 ROUTE 46
- City
- LODI
- State
- NJ
- ZIP
- 07644
- Mailing
- 51 GARDEN STREET APT #2, NEWARK, NJ 07105
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 20
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.100 A
- Issued
- Dec 3, 2024
- Penalty
- Initial $7,098 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. a) 313 Route 46 Lodi New Jersey Ground level: Employees working on the ground level under workers engaged in roofing activities about +/- 20 feet above were exposed to struck by hazards and were not protected by any means of head protection, on or about 7/3/24.
Recent events (3)
- — F (S) $3000
- — C (S) $7098
- — Z (S) $7098
1926.102 A01
- Issued
- Dec 3, 2024
- Penalty
- Initial $6,084 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees did not use eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) 313 Route 46 Lodi New Jersey on the Roof: Employees were exposed to eye injuries from flying objects while shingles were being installed with a pneumatic nail gun. Employees were not using any type of eye protection, on or about 7/3/24.
Recent events (3)
- — F (S) $2500
- — C (S) $6084
- — Z (S) $6084
1926.102 B01 I
- Issued
- Dec 3, 2024
- Penalty
- Initial $6,084 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.102(b)(1)(i): Protective eye and face protection devices did not comply with consensus standard; ANSI/ISEA Z87.1-2010, Occupational and Educational Personal Eye and Face Protection Devices, incorporated by reference in § 1926.6: a) 313 Route 46 Lodi New Jersey, on the roof: RRC Home Improvement did not ensure that the employee operating a pneumatic nail gun was wearing appropriate eye protection compliant with consensus standard ANSI/ISEA Z87.1-2010, Occupational and Educational Personal Eye and Face Protection Devices , on or about 7/3/24.
Recent events (3)
- — F (S) $2500
- — C (S) $6084
- — Z (S) $6084
1926.150 C01 I
- Issued
- Dec 3, 2024
- Penalty
- Initial $6,084 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: a) RRC Home Improvement Inc, does not ensure that employees have available firefighting equipment at the jobsite. The employer did not provide any firefighting equipment at the jobsite. Gasoline fueled compressor was being used to power pneumatic nail guns. Extra gasoline was store in 5-gallon plastic containers at the site, on or about 7/3/24.
Recent events (3)
- — F (S) $2500
- — C (S) $6084
- — Z (S) $6084
1926.452 J02
- Issued
- Dec 3, 2024
- Abate by
- Dec 9, 2024
- Penalty
- Initial $7,098 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Building Exterior right side: Employees were working on a pump jack scaffold that was not secured at the bottom by rigid triangular or equivalent braces, on or about 7/3/24. b) Building Exterior in front of apartment 19W: Employees were working on a pump jack scaffold that was not secured at the bottom by rigid triangular or equivalent braces, on or about 7/3/24.
Recent events (3)
- — F (S) $3000
- — C (S) $7098
- — Z (S) $7098
1926.501 B13
- Issued
- Dec 3, 2024
- Abate by
- Dec 9, 2024
- Penalty
- Initial $70,982 · Current $32,625 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system. RRC Home Improvement does not ensure that employees use appropriate fall protection while engaged in residential construction activities 6 feet (1.8m) or more above lower levels. The violation was most recently observed on or about 7/3/2024, at or near 313 Route 46 Lodi New Jersey on the Roof. Employee #1 was installing shingles and was not protected from fall hazards of +/- 20 feet. The employee wore an inadequate personal fall arrest system by not utilizing a lanyard, anchor point, or lifeline .
Recent events (3)
- — F (W) $32625
- — C (W) $70982
- — Z (W) $70982
1926.503 A01
- Issued
- Dec 3, 2024
- Abate by
- Dec 30, 2024
- Penalty
- Initial $70,982 · Current $32,625 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) 313 Route 46 Lodi New Jersey and at the Corporate Offices at 58 Christie Street, Newark, NJ: Employees engaged in residential re-roofing activities were not provided with a training program which would help workers identify and minimize fall hazards, on or about 7/3/24.
Recent events (3)
- — F (W) $32625
- — C (W) $70982
- — Z (W) $70982
More inspections at RRC Home Improvement, INC.
View RRC Home Improvement, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238350)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347600652.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.