OSHA Inspection: RADIO FREQUENCY SYSTEMS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RADIO FREQUENCY SYSTEMS, INC. in 200 PONDVIEW DRIVE, MERIDEN, CT 06450 (NAICS 334220). OSHA activity number 342806387.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Radio Frequency Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Radio Frequency Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
200 PONDVIEW DRIVE
City
MERIDEN
State
CT
ZIP
06450
Mailing
200 PONDVIEW DRIVE, MERIDEN, CT 06450
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334220
Employees
278
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 19, 2018
Abate by
Mar 8, 2018
Penalty
Initial $12,934 · Current $8,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.     WORKSHOP:   The energy control procedures did not include all the energy sources and alternative measures in the machine specific for the employees of the hosting and contract employers during servicing and maintenance of equipment, such as (but not limited to) the Jacketing EJ extrusion lines    On/or about November 28, 2017, an extrusion head that was in the process of being moved from a work table onto a transfer cart fell onto an employee's abdomen and leg resulting in broken bone injuries from the incident. The extrusion head, which was one of hazardous energy sources was not appropriately secured to prevent from displacement.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $12934

1910.147 C07 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 19, 2018
Abate by
Mar 8, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees.   WORKSHOP:   The employees, as "authorized, affected, and/or other types" were not provided with training and information in the controlling of potentially hazardous and unexpected releases of energy sources and/or alternative measures (lo/to) during service and maintenance and change over of the extrusion heads at the Jacketing EJ lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Radio Frequency Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342806387.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.