WEST MEMPHIS, AR —
OSHA Inspection: FAMILY DOLLAR DISTRIBUTION CENTER
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of FAMILY DOLLAR DISTRIBUTION CENTER in 1800 FAMILY DOLLAR DR., WEST MEMPHIS, AR 72301 (NAICS 493110). OSHA activity number 342877503.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FAMILY DOLLAR DISTRIBUTION CENTER
- Site address
- 1800 FAMILY DOLLAR DR.
- City
- WEST MEMPHIS
- State
- AR
- ZIP
- 72301
- Mailing
- 500 VOLVO PARKWAY, CHESAPEAKE, VA 23320
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 500
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 F02 I
- Issued
- May 4, 2018
- Abate by
- May 18, 2018
- Penalty
- Initial $12,675 · Current $7,605 Reduced
General-duty citation text
29 CFR 1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures: On or about January 9, 2018, the host employer and a contractor did not inform each other of their respective lockout or tagout procedures before work began. A host employer maintenance technician turned off the main breaker to King National Air System, FD5 that a contract employee was repairing to de-energize it.
Recent events (2)
- — I (S) $7605
- — Z (S) $12675
1910.147 F02 II
- Issued
- May 4, 2018
- Abate by
- May 18, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(2)(ii): The onsite employer did not ensure that his or her personnel understood and complied with restrictions and prohibitions of the outside employer's energy control procedures: On or about January 9, 2018, the host employer and a contractor did not ensure the authorized employee that de-energized the King National Air System FD5 understood and complied with the contractor energy control procedures.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.176 B
- Issued
- May 4, 2018
- Abate by
- May 18, 2018
- Penalty
- Initial $10,163 · Current $6,098 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage was not secure. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse. On or about January 11, 2018 and there prior to, the employer stacked pallets and boxes of merchandise on unstable dented storage racks in the warehouse, exposing employees to struck-by hazards from falling objects in these areas as follows: a. Aisle 1 - 1 dented structural brace support member. b. Aisle 19 - 2 dented structural brace support members. c. Aisle 21 - 2 dented structural brace support members.
Recent events (2)
- — I (S) $6097.8
- — Z (S) $10163
More inspections at Family Dollar Distribution Center
View Family Dollar Distribution Center's full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342877503.