On , OSHA opened a referral safety inspection of MEADVILLE PLATING COMPANY, INC. in 10775 FRANKLIN PIKE ROAD, MEADVILLE, PA 16335 (NAICS 332813). OSHA activity number 342929221.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Meadville Plating Company, INC. — free Get an email when a new federal OSHA severe-injury report for Meadville Plating Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10775 FRANKLIN PIKE ROAD
City
MEADVILLE
State
PA
ZIP
16335
Mailing
10775 FRANKLIN PIKE ROAD, MEADVILLE, PA 16335
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
14
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 3 exposed
Issued
May 23, 2018
Abate by
Jun 19, 2018
Penalty
Initial $2,956 · Current $1,960 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees from struck by hazards in that hoists were not being inspected and lack of pendant markings:        A.)  Meadville Plating Company, Inc. - On or about 2/6/18, and at times prior thereto, frequent and periodic hoist inspections were not being performed on the hoists.  Deficiencies on the hoists included, but were not limited to, the pendant box not being marked.  Hoists were utilized to lift parts weighing up to 700 lbs.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2956

1910.37 A04

Serious Gravity 1 1 instance 6 exposed
Issued
May 23, 2018
Abate by
Jun 19, 2018
Penalty
Initial $2,217 · Current $1,500 Reduced
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:      A.)  Meadville Plating Company, Inc. - On or about 2/6/18, and at times prior thereto, emergency lighting was not operational in areas including, but not limited to, plating tanks.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2217

1910.215 A04

Serious Gravity 5 1 instance 3 exposed
Issued
May 23, 2018
Abate by
Jun 19, 2018
Penalty
Initial $2,956 · Current $1,500 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:        A.) Meadville Plating Company, Inc.; machine shop; - On or about 2/6/18, and at times prior thereto,  the work rest on the grinder was adjusted to 1/2 inch.  The grinder included, but were not limited to, the Strong Carlisle and Hammond bench grinder.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2956

1910.215 B09

Serious Gravity 5 1 instance 3 exposed
Issued
May 23, 2018
Abate by
Jun 19, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    A.) Meadville Plating Company, Inc.; machine shop; - On or about 2/6/18, and at times prior thereto,  the tongue guard on the grinder was adjusted to 1-1/2 inch.  The grinder, included, but were not limited to, the Strong Carlisle and Hammond bench grinder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Other-than-serious 1 instance 2 exposed
Issued
May 23, 2018
Abate by
Jun 19, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   A.)  Meadville Plating Company, Inc.; machine shop - On or about 2/6/18, and at times prior thereto, the area in front of a 220 volt electrical panel was used for storage.  Items stored in front of the electrical panel box, included, but were not limited to, absorbent and scrap steel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0