MEADVILLE, PA —
OSHA Inspection: MEADVILLE PLATING COMPANY, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of MEADVILLE PLATING COMPANY, INC. in 10775 FRANKLIN PIKE, MEADVILLE, PA 16335 (NAICS 332813). OSHA activity number 344666268.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MEADVILLE PLATING COMPANY, INC.
- Site address
- 10775 FRANKLIN PIKE
- City
- MEADVILLE
- State
- PA
- ZIP
- 16335
- Mailing
- 10775 FRANKLIN PIKE, MEADVILLE, PA 16335
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 13
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 3, 2020
- Abate by
- Apr 29, 2020
- Penalty
- Initial $2,622 · Current $1,200 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees from struck by hazards in that hoists were not being inspected and lack of pendant markings: A.) Meadville Plating Company, Inc. - On or about 3/2/20, and at times prior thereto, frequent inspections were not being performed on the hoists. Hoists were used to lift parts weighing up to 700 lbs. B.) Meadville Plating Company, Inc. - On or about 3/2/20, and at times prior thereto, deficiencies on the hoists, included, but were not limited to, the pendant box was not legibly marked. Hoists were used to lift parts weighing up to 700 lbs. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation. This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (2)
- — I (S) $1200
- — Z (S) $2622
1910.303 G01 II
- Issued
- Apr 3, 2020
- Penalty
- Initial $1,671 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: A.) Meadville Plating Company, Inc. - On or about 3/2/20, and at times prior thereto, the area in front of a 240 volt electrical panel box was used for storage. Items stored in front of the electrical panel box, included, but were not limited to a 55 gallon container of sludge. .
Recent events (2)
- — I (S) $1200
- — Z (S) $1671
More inspections at Meadville Plating Company, INC.
View Meadville Plating Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332813)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344666268.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.