Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUPERIOR DAIRY, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUPERIOR DAIRY, INC in 4719 NAVARRE RD. SW, CANTON, OH 44706 (NAICS 112120). OSHA activity number 342968971.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Superior Dairy, INC — free Get an email when a new federal OSHA severe-injury report for Superior Dairy, INC is published. One employer, no account, unsubscribe in one click.
Establishment
SUPERIOR DAIRY, INC
Site address
4719 NAVARRE RD. SW
City
CANTON
State
OH
ZIP
44706
Mailing
4719 NAVARRE RD. SW, CANTON, OH 44706
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
112120
Employees
50
Ownership type
A

5 citations on file for this inspection.

1910.146 C05 II H

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 30, 2018
Penalty
Initial $9,054 · Current $5,432 Reduced
29 CFR 1910.146(c)(5)(ii)(H): Employees entered into permit spaces that met the conditions set forth in 29 CFR 1910.146(c)(5)(i), but the employer did not verify that the space was safe for entry and that the measures required by 29 CFR 1910.146(c)(5)(ii(a) had been taken:    On or about February 12, 2018, the employer failed to ensure that a permit required confined space was safe for entry prior to employees entering. An employee was tasked with servicing the office air handling unit. At the time the equipment was a permit required confined space being that the hazardous energies present on the equipment were not controlled.
Recent events (2)
  • — I (S) $5432
  • — Z (S) $9054

1910.147 D03

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  On or about February 12, 2018 the employer failed to ensure that the energy isolating devices of the office air handling unit were located and operated to isolate the energy sources. An employee was tasked with servicing the unit without controlling the hazardous energies prior to performing the work. The employee only utilized the on/off switch located at the control panel. Hazardous energy sources include steam, kinetic and electrical.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 C07 I

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 30, 2018
Abate by
May 8, 2018
Penalty
Initial $9,054 · Current $0 Reduced
29 CFR 1910.146(c)(7)(i): A space classified by the employer as permit-required confined space was reclassified as a non-permit confined space when all hazards within the space were not eliminated without entry into the space:    On or about February 22, 2018 the employer reclassified a permit required confined space (office air handling unit)  as non-permit required without eliminating all of the hazards associated within the space. The employer had designated the space as permit required and posted warning signs on the unit. The space can only be reclassified at the time that the equipment has its hazardous energies controlled by use of lock out and tag out.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9054

1910.147 C04 I

Serious Gravity 10 2 instances 2 exposed
Issued
Apr 30, 2018
Penalty
Initial $9,054 · Current $5,432 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about February 12, 2018 the employer failed to ensure that machine specific procedures were developed for the office air handling unit. An employee was tasked with servicing the equipment prior to procedures being in place. Hazardous energies present on the equipment include electrical, steam, and kinetic.
Recent events (2)
  • — I (S) $5432
  • — Z (S) $9054

1910.147 C06 I

Serious Gravity 10 2 instances 25 exposed
Issued
Apr 30, 2018
Abate by
Sep 18, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.    On or about February 22, 2018 the employer had not performed an annual inspection of the energy control procedures for equipment in the facility. Equipment includes conveyors, air handling units, bottling equipment, boxing equipment, and palletizers. Hazardous energy sources include pneumatic, kinetic, mechanical, hydraulic, steam, and electrical.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Superior Dairy, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342968971.