OSHA Inspection: DENT WIZARD INTERNATIONAL

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DENT WIZARD INTERNATIONAL in 100 GRANBY STREET, BLOOMFIELD, CT 06002 (NAICS 811111). OSHA activity number 343036802.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dent Wizard International — free Get an email when a new federal OSHA severe-injury report for Dent Wizard International is published. One employer, no account, unsubscribe in one click.
Site address
100 GRANBY STREET
City
BLOOMFIELD
State
CT
ZIP
06002
Mailing
4710 EARTH CITY EXPRESSWAY, BRIDGETON, MO 63044
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
15
Ownership type
A

14 citations on file for this inspection.

1910.37 A04

Serious Gravity 1 2 instances 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $5,543 · Current $3,326 Reduced
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  A.  On or about March 27, 2018, Wheel Shop:  In the following instances, hardware on emergency exit doors was damaged:  1.  North side of the building, rear:  The self-retracting arm on the identified emergency exit door was damaged and detatched from the door frame.  The defective safeguard would not keep the door closed in case of emergency.    2.  GFS Paint Mixing Room:   The self-retracting arm on the exit door from the paint mixing room was damaged and detatched from the door frame.  The defective safeguard would not keep the door closed in case of emergency.
Recent events (2)
  • — I (S) $3325.8
  • — Z (S) $5543

1910.37 B02

Serious Gravity 1 1 instance 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  A.  On or about March 27, 2018, Wheel Shop:  The Vendor Door on the north side of the shop, front, was not provided with an illuminated EXIT sign.  The door was identified as an emergency exit in the site's fire exit map.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $9,239 · Current $5,543 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:  A.  On or about March 27, 2018, Wheel Shop Production Area:  The Lehigh CNC lathe had a disabled interlock.  The enclosure doors were able to be opened during operation, allowing access to the rotating point of operation.
Recent events (2)
  • — I (S) $5543.4
  • — Z (S) $9239

1910.212 B

Serious Gravity 5 1 instance 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:   A.  On or about March 27, 2018, Wheel Shop, Welding Area:  A Ryobi BG828G bench grinder was used to grind down the tungsten electrode tip used in TIG welding operations.  The equipment was not secured to the metal cart on which it was placed, to prevent it from moving during use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $7,391 · Current $4,435 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:   A.  On or about March 27, 2018, Wheel Shop, Welding Area: The work rest on the Ryobi BG828G bench grinder had not been adjusted to within one eighth inch of the abrasive wheel.  The gap between the work rest and the abrasive wheel measured one half inch.  Work being held against the wheel could be pulled into the gap between the work rest and the abrasive wheel, exposing employees to injury.
Recent events (2)
  • — I (S) $4434.6
  • — Z (S) $7391

1910.215 B09

Serious Gravity 5 1 instance 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   A.  On or about March 27, 2018, Wheel Shop, Welding Area:  The tongue guard on the left side of the Ryobi BG828B bench grinder was missing, allowing an opening of greater than one fourth inch between the abrasive wheel and the equipment enclosure.  The opening measured one half inch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 5 1 instance 15 exposed
Issued
Apr 18, 2018
Penalty
Initial $7,391 · Current $4,435 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  A.  On or about March 27, 2018, Wheel Shop,  Wheel Balancing area near the Oxygen Tank:  A Central Machinery 31-inch diameter metal-encased pedestal fan was not grounded.  Voltage was detected in the metal enclosure guard.  The flexible cordset for the fan was damaged as it was bent in half and spliced, with the two halves taped together.
Recent events (2)
  • — I (S) $4434.6
  • — Z (S) $7391

1910.305 G01 IV A

Serious Gravity 5 3 instances 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   A.  On or about March 27, 2018, in the following instances, flexible extension cords were used in lieu of the fixed wiring of the building to power equipment:  1.  Wheel Shop, at the Steelman Bake Oven:  Five 31-inch diameter metal encased pedestal fans used to cool parts were energized by flexible extension cords which were run underneath the oven to outlets on the South wall of the building.  2.  Wheel Shop, Wheel Balancing Area near the Oxygen Tank:  A Central Machinery 31-inch diameter metal-encased pedestal fan was energized through an extension cord plugged into a wall outlet around the corner, behind a tire rack.  3.  Wheel Shop, Production Area, near Electrical Panel PP3:  A stereo and several speakers were powered through a yellow extension cord that ran across the shop floor from a wall-mounted outlet box on the wall of the Welding Area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV D

Serious Gravity 5 1 instance 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces:   A.  On or about March 27, 2018, Wheel Shop near the Steelman Bake Oven:  Flexible extension cords used to energize five 31-inch diameter metal-encased pedestal fans used for cooling parts were subject to damage as they were bound together with zip-ties and affixed to conduit on the South wall of the building behind the oven.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 II

Serious Gravity 5 1 instance 15 exposed
Issued
Apr 18, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap:  A.  On or about March 27, 2018, Wheel Shop,  Wheel Balancing area near the Oxygen Tank:  A Central Machinery 31-inch diameter metal-encased pedestal fan was not grounded.  Voltage was detected in the metal enclosure guard.  The flexible cordset for the fan was damaged as it was bent in half and spliced, with the two halves taped together.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):   A.  On or about March 27, 2018, Wheel Shop at Powder Coating Booth:   The insulation on the flexible cordset for the Nordson Encore Powder Coating Sprayer control panel had been pulled from its fitting, exposing the energized wires.  The equipment was powered through an outlet on the side of the Powder Coating Booth, along the main aisle into the shop.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.32 A04

Other-than-serious 1 instance 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30:  A.  On or about March 27, 2018, the employer had not posted a copy of the OSHA 300A Annual Summary of Work-Related Injuries and Illnesses for 2017.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   A.  On or about March 27, 2018, Wheel Shop:  Access to electrical panel PP3 was blocked by the storage of a red handtruck, a metal work lamp and a Tennant floor cleaning machine.  The breakers in the panel controlled equipment in the shop including but not limited to a welder compressor, CNC lathe, exhaust fans and emergency lights.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 A02 II

Other-than-serious 1 instance 15 exposed
Issued
Apr 18, 2018
Abate by
Jun 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(ii): Temporary wiring was not removed immediately upon completion of the project or purpose for which the wiring was installed:   A.  On or about March 27, 2018, Wheel Shop:  A yellow extension cord, plugged in to a 4-receptacle wall outlet in the Welding Area ran across the floor to an area near electrical panel PP3, where it provided power to a stereo and speaker system. The equipment was not being used at the time of the inspection and had not been unplugged after use.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Dent Wizard International's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343036802.