Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DENT WIZARD INTERNATIONAL

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DENT WIZARD INTERNATIONAL in 100 GRANBY STREET, BLOOMFIELD, CT 06002 (NAICS 811121). OSHA activity number 344064191.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dent Wizard International — free Get an email when a new federal OSHA severe-injury report for Dent Wizard International is published. One employer, no account, unsubscribe in one click.
Site address
100 GRANBY STREET
City
BLOOMFIELD
State
CT
ZIP
06002
Mailing
100 GRANBY STREET, BLOOMFIELD, CT 06002
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
17
Ownership type
A

5 citations on file for this inspection.

1910.106 E02 IV A

Serious Gravity 5 5 instances 2 exposed
Issued
Jul 15, 2019
Penalty
Initial $7,577 · Current $3,789 Reduced
29 CFR 1910.106(e)(2)(iv)(a): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use:  GFS Mixing Room:  On, or about, June 5, 2019, the waste container and several small mixing containers were left open in the room.
Recent events (2)
  • — I (S) $3788.5
  • — Z (S) $7577

1910.106 E06 I

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors:   GFS Paint Mixing Room:  On, or about, June 5, 2019, the following containers of flammable liquid were not properly grounded:  A.  Waste container located under Gun Cleaning Sink. B.  Five gallon container of Key 80 Fast Urethane Grade Reducer that was provided with a dispenser pump.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 I07

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 15, 2019
Penalty
Initial $6,440 · Current $3,220 Reduced
29 CFR 1910.107(i)(7): Objects being painted or coated were not maintained in metallic contact with the conveyor or other grounded support. Hooks were not regularly cleaned to insure this contact and areas of contact did not have sharp points or knife edges where possible. Points of support of the object were not concealed from random spray where feasible and where the objects being sprayed are supported from a conveyor, the point of attachment to the conveyor was not located as to not collect spray material during normal operation:   Powder Coating Booth:  On, or about, June 5, 2019, the hooks provided to hang rims during powder coating operations were coated with the powder and continuity could not be found between the coated hook and support bar.  The coating that was applied using an electrostatically was Akzo Nobel A4740, a combustible powder.
Recent events (2)
  • — I (S) $3220
  • — Z (S) $6440

1910.37 A04

Repeat Gravity 1 1 instance 8 exposed
Issued
Jul 15, 2019
Penalty
Initial $28,415 · Current $14,208 Reduced
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  GFS Paint Mixing Room:  On, or about, June 5, 2019, the self-closing door provided for the storage/mixing room was not closing properly, leaving a six inch wide gap.    Dent Wizard International was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection Number 1303680, Citation Number 1, Item Number 1a and was affirmed as a Final Order on May 11, 2018, with respect to a workplace located at Bloomfield, Connecticut.
Recent events (2)
  • — I (R) $14207.5
  • — Z (R) $28415

1910.305 G01 IV A

Repeat 2 instances 10 exposed
Issued
Jul 15, 2019
Penalty
Initial $9,475 · Current $4,738 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Wheel Shop:  In the following locations, extension cords were used to energize fans:  A.  Torch Burning Area:  An Air Master pedestal fan was used to blow smoke out of the employees breathing zone and out the garage door when the burning torch was used to clean rims.  B.  Rear of Shop:  A Central Machinery floor fan was used to ventilate heat air out of the building that was generated from the powder coating curing booth.  Dent Wizard International previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection Number 1303680, Citation Number 1, Item Number 4b and was affirmed as a Final Order on May 11, 2018, with respect to a workplace located at Bloomfield, Connecticut.
Recent events (2)
  • — I (R) $4737.5
  • — Z (R) $9475

View Dent Wizard International's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344064191.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.