Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DENT WIZARD INTERNATIONAL

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DENT WIZARD INTERNATIONAL in 100 GRANBY STREET, BLOOMFIELD, CT 06002 (NAICS 811111). OSHA activity number 343043352.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dent Wizard International — free Get an email when a new federal OSHA severe-injury report for Dent Wizard International is published. One employer, no account, unsubscribe in one click.
Site address
100 GRANBY STREET
City
BLOOMFIELD
State
CT
ZIP
06002
Mailing
4710 EARTH CITY EXPRESSWAY, BRIDGETON, MO 63044
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
15
Ownership type
A

5 citations on file for this inspection.

1910.101 B

Serious Gravity 1 1 instance 2 exposed
Issued
May 21, 2018
Abate by
Jul 9, 2018
Penalty
Initial $5,543 · Current $3,326 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:   WELDING AREA  On, or about March 27, 2018, a compressed gas cylinder that contained nitrogen, was not stored securely to prevent falling. (Ref. CGA P-1-1965 Section 3.3.1 referencing 2006 CGA P-1 Section 5.7.4.)
Recent events (2)
  • — I (S) $3325.8
  • — Z (S) $5543

1910.107 B09

Serious Gravity 1 2 instances 5 exposed
Issued
May 21, 2018
Abate by
Jul 9, 2018
Penalty
Initial $5,543 · Current $3,326 Reduced

Hazardous substances M110

29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:   On, or about March 27, 2018, the 3 foot clear space was not maintained on all sides at the following locations:    a) The flammable spray booth had material, such as, but not limited to tires, and a flammable storage cabinet stored along the perimeter of the booth.   b) The powder coating booth had material such as, but not limited to a wooden ladder stored along the right side of the booth.
Recent events (2)
  • — I (S) $3325.8
  • — Z (S) $5543

1910.107 I08

Serious Gravity 5 1 instance 5 exposed
Issued
May 21, 2018
Abate by
Jul 9, 2018
Penalty
Initial $7,391 · Current $4,435 Reduced

Hazardous substances M110

29 CFR 1910.107(i)(8): The electrical equipment was not interlock with the ventilation of the spraying area that the equipment could not be operated unless the ventilation fans were in operation:  GFS POWDER COATING BOOTH  On, or about March 27, 2018, the Encore LT, manual powder spray system was not interlocked with the ventilation system of the GFS (Powder Non-Recovery) Booth when employees used INTERPON, A4740 Clear, which is a combustible coating.
Recent events (2)
  • — I (S) $4434.6
  • — Z (S) $7391

1910.1200 H03 IV

Serious Gravity 1 1 instance 4 exposed
Issued
May 21, 2018
Abate by
Jul 9, 2018
Penalty
Initial $5,543 · Current $3,326 Reduced

Hazardous substances 2460

29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the  safety data sheet, including the order of information and how employees could obtain and use the appropriate hazard information:   SHOP AREA  On, or about March 27, 2018, The employer failed to include an explanation of the safety data sheets, including the order of information and how employees could obtain and use the appropriate hazard information when employees used chemicals, such as, but not limited to REDUCER, which contained toluene and is a respiratory irritant.
Recent events (2)
  • — I (S) $3325.8
  • — Z (S) $5543

1910.1200 F09

Other-than-serious 1 instance 4 exposed
Issued
May 21, 2018
Abate by
Jul 9, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 2460

29 CFR 1910.1200(f)(9): The employer did not ensure that labels or other forms of warning were legible, in English, and prominently displayed on the container, or readily available in the work area throughout each work shift:  SHOP AREA  On, or about March 27, 2018, a bottle reported to contain Prep-All, a reducer that contained acetone, is flammable  and is a skin and eye irritant did not have labels or other forms of warning displayed on the container or in the work area.