Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J & B INSTALLATIONS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J & B INSTALLATIONS, INC. in B & W SUPPLY, 510 3RD STREET, ITHACA, NY 14850 (NAICS 238160). OSHA activity number 343189601.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & B Installations, INC. — free Get an email when a new federal OSHA severe-injury report for J & B Installations, INC. is published. One employer, no account, unsubscribe in one click.
Site address
B & W SUPPLY, 510 3RD STREET
City
ITHACA
State
NY
ZIP
14850
Mailing
732 VISIONS DRIVE, SKANEATELES FALLS, NY 13153
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
80
Ownership type
A

6 citations on file for this inspection.

1926.453 B02 V

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 13, 2018
Penalty
Initial $6,467 · Current $3,883 Reduced
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:       a) East side of building, entry area, on or about 5-24-18:  One employee was operating an articulating, extensible boom, aerial lift, without a safety harness or body belt connected, exposing the employee to a fall hazard of 16 feet 7 inches.       b) North side of building, on or about 5-24-18:  One employee was working in a telescopic telehandler personnel basket without a safety harness or body belt connected, exposing the employee to a fall hazard of 14 feet 4 inches.
Recent events (2)
  • — I (S) $3882.8
  • — Z (S) $6467

1926.501 B10

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 13, 2018
Penalty
Initial $6,467 · Current $3,883 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels and 50-feet (15.25 m) wide or less, was not protected from falling by guardrail systems, safety net systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:       a) East side of building, flat roof above entry area, on or about 5-24-18:  Two employees were working on a flat roof with unprotected sides and edges, and not protected from falls, exposing the employees to a fall hazard of 16 feet 7 inches.
Recent events (2)
  • — I (S) $3882.8
  • — Z (S) $6467

1926.602 C01 II

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 13, 2018
Abate by
Jul 23, 2018
Penalty
Initial $6,467 · Current $0 Reduced
29 CFR 1926.602(c)(1)(ii): Modifications or additions which affect the capacity or safe operation of the equipment were made without the manufacturer's written approval:    a) North side of building, on or about 5-24-18:  Two employees were working in an aftermarket personnel platform, mounted on a telehandler, in a manner affecting safe operation and without manufacturers approval.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $0
  • — Z (S) $6467

1926.602 C01 VIII A

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 13, 2018
Penalty
Initial $0 · Current $3,883
29 CFR 1926.602(c)(1)(viii)(A): The safety platform was not firmly secured to the lifting carriage and/or forks:       a) North side of building, on or about 5-24-18:  Two employees were working in an aftermarket personnel platform, mounted on a telehandler, and was not secured or chained to the forks or backrest of the lift.
Recent events (2)
  • — I (S) $3882.8
  • — Z (S) $0

1926.602 C01 VIII B

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 13, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.602(c)(1)(viii)(B): Means were not provided whereby personnel on the platform could shut off power to the truck:    a) North side of building, on or about 5-24-18:  Two employees were working in an aftermarket personnel platform, mounted on a telehandler, and it was being used with no means for the personnel to operate the controls.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Other-than-serious 1 instance 2 exposed
Issued
Jul 13, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) East side of building, flat roof above entry area, on or about 5-24-18:  Two employees were using a fiberglass extension ladder for access to a flat roof, with side rails that were 28 inches above the landing surface, exposing the employees to a fall hazard of  16 feet 7 inches.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View J & B Installations, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343189601.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.