PHILADELPHIA, PA —
OSHA Inspection: MELROSE ENTERPRISES, LTD.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of MELROSE ENTERPRISES, LTD. in 3525 I STREET, PHILADELPHIA, PA 19134 (NAICS 238140). OSHA activity number 343374369.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MELROSE ENTERPRISES, LTD.
- Site address
- 3525 I STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19134
- Mailing
- 130 DICKERSON ROAD, NORTH WALES, PA 19454
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 28
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.451 D16
- Issued
- Feb 1, 2019
- Abate by
- Feb 21, 2019
- Penalty
- Initial $13,260 · Current $13,260
General-duty citation text
29 CFR 1926.451(d)(16): The suspension scaffold power-operated hoist or manually operated hoist did not have, in addition to the normal operating brake, a braking device or locking pawl which engages automatically when a hoist makes either of the following uncontrolled movements: an instantaneous change in momentum or an accelerated overspeed. a) Jobsite: 3525 I Street, Philadelphia, PA 19134 building Rooftop - Employees conducting masonry work from a two point suspended scaffold on a 5th story window were exposed to fall hazards. A hoisting device equipped with a brake capable of stopping uncontrolled movements was not utilized to prevent the scaffold from dropping. This was documented to occur on August 8, 2018.
Recent events (3)
- — F (S) $13260
- — C (S) $13260
- — Z (S) $13260
1926.451 D17
- Issued
- Feb 1, 2019
- Abate by
- Feb 21, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(d)(17): Manually operated hoists did not have a positive crank force to descend: a) Jobsite: 3525 I Street, Philadelphia, PA 19134 building Rooftop - Employees conducting masonry work from a two point suspended scaffold on a 5th story window were exposed to fall hazards. The manually operated suspension hoists were not equipped with positive crank force devices to control descend and prevent the scaffold from dropping. This was documented to occur on August 8, 2018.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 G01 II
- Issued
- Feb 1, 2019
- Abate by
- Feb 21, 2019
- Penalty
- Initial $13,260 · Current $13,260
General-duty citation text
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system: Jobsite: 3525 I Street, Philadelphia, PA 19134 building Rooftop - Employees conducting masonry work from a two point suspended scaffold on a 5th story window were exposed to fall hazards. Each employee was not adequately protected from falling. a) An employee wearing a full body harness was provided a vertical synthetic rope lifeline to utilize with a shock absorbing lanyard and rope grab, that did not prevent the employee from falling. This was documented to occur on August 8, 2018 when the employee fell approximately 30' from the scaffold. b) An appropriate guardrail system consisting of a top railing measuring between 36" and 45" above the platform and either midrails, screens, mesh, or other intermediate vertical member no more than 19" apart were not provided on the scaffold. This was documented to occur on August 8, 2018 when the employee fell approximately 30' from the scaffold.
Recent events (3)
- — F (S) $13260
- — C (S) $13260
- — Z (S) $13260
1926.451 G03 I
- Issued
- Feb 1, 2019
- Abate by
- Feb 21, 2019
- Penalty
- Initial $10,210 · Current $10,210
General-duty citation text
29 CFR 1926.451(g)(3)(i): Verical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion. Safe points of anchorage include structural members of buildings, but do not include standpipes, vents, other piping systems, electrical conduit, outrigger beams, or counterweights. a) Jobsite: 3525 I Street, Philadelphia, PA 19134 building Rooftop - Employees conducting masonry work from a two point suspended scaffold on a 5th story window were exposed to fall hazards. A vertical life line used by an employee was tied around an HVAC vent instead of a safe point of anchorage. Vertical life lines were also not protected from sharp edges where they were draped over the building's parapet wall. This was documented to occur on August 8, 2018.
Recent events (3)
- — F (S) $10210
- — C (S) $10210
- — Z (S) $10210
1926.451 G04 I
- Issued
- Feb 1, 2019
- Abate by
- Feb 21, 2019
- Penalty
- Initial $10,210 · Current $10,210
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. a) Jobsite: 3525 I Street, Philadelphia, PA 19134 building Rooftop - Employees conducting masonry work from a two point suspended scaffold on a 5th story window were exposed to fall hazards. A complete guardrail system consisting of either midrails, screens, mesh, or other intermediate vertical member no more than 19" apart was not provided between the top railing and the scaffold platform. This was documented to occur on August 8, 2018.
Recent events (3)
- — F (S) $10210
- — C (S) $10210
- — Z (S) $10210
1926.451 G04 II
- Issued
- Feb 1, 2019
- Abate by
- Feb 21, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(ii): The top edge height on all suspended scaffolds where both a guardrail and a personal fall arrest system are required were not between 36 inches (0.9 m) and 45 inches (1.2 m) above the platform surface: a) Jobsite: 3525 I Street, Philadelphia, PA 19134 building Rooftop - Employees conducting masonry work from a two point suspended scaffold on a 5th story window were exposed to fall hazards. The top edge height of the guardrail was 29 1/2 inches above the platform. This was documented to occur on August 8, 2018.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.454 C02
- Issued
- Feb 1, 2019
- Abate by
- Feb 21, 2019
- Penalty
- Initial $10,210 · Current $0 Reduced
General-duty citation text
29 CFR 1926.454(c)(2): 29 CFR 1926.454(c)(2): The employer failed to retrain employees where changes in the types of scaffolds, fall protection, falling object protection, or other equipment presented a hazard about which they had not been previously trained: a) Jobsite: 3525 I Street, Philadelphia, PA 19134 building Rooftop - Employees conducting masonry work from a two point suspended scaffold on a 5th story window were exposed to fall hazards. When employees were assigned to use a different block and fall suspended scaffold, they were not properly retrained on its use including but not limited to the installation of appropriate guardrails systems, and how to safely hoist and descend the platform.
Recent events (3)
- — F (S) $0
- — C (S) $10210
- — Z (S) $10210
1926.451 D05 III
- Issued
- Feb 1, 2019
- Abate by
- Feb 21, 2019
- Penalty
- Initial $20,420 · Current $20,240 Reduced
General-duty citation text
29 CFR 1926.451(d)(5)(iii): Supporting devices were not secured against movement by tiebacks installed at right angles to the face of the building or structure, or opposing angle tiebacks were not installed and secured to a structurally sound point of anchorage on the building or structure. Sound points of anchorage include structural members, but do not include standpipes, vents, other piping systems, or electrical conduit. a) Jobsite: 3525 I Street, Philadelphia, PA 19134 building Rooftop - Employees conducting masonry work from a two point suspended scaffold on a 5th story window were exposed to fall hazards. A single tie back used to secure one of the two parapet hooks was not installed at a right angle to the building's parapet, nor was a structurally sound point of anchorage used to secure the tieback as it was attached to an HVAC unit. This was documented to occur on August 8, 2018. Melrose Enterprises, Ltd. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(d)(5)(iii), which was contained in OSHA inspection number 931310, citation number 1 item number 3 and was affirmed as a final order on February 14, 2014, with respect to a workplace located at 170 S Independence Mall W, Ste 960, Philadelphia, PA 19106.
Recent events (3)
- — F (S) $20240
- — C (R) $20420
- — Z (R) $20420
More inspections at Melrose Enterprises, LTD.
View Melrose Enterprises, LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343374369.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.