Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUALITY RESTORATION & ROOFING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of QUALITY RESTORATION & ROOFING INC. in 304 ACORN STREET, NORTH AURORA, IL 60542 (NAICS 238160). OSHA activity number 343453643.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Restoration & Roofing INC. — free Get an email when a new federal OSHA severe-injury report for Quality Restoration & Roofing INC. is published. One employer, no account, unsubscribe in one click.
Site address
304 ACORN STREET
City
NORTH AURORA
State
IL
ZIP
60542
Mailing
8249 NATOMA, BURBANK, IL 60459
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

4 citations on file for this inspection.

1903.19 D01

Other-than-serious 1 instance 2 exposed
Issued
Jan 10, 2019
Abate by
Mar 4, 2019
Penalty
Initial $311 · Current $311
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.     Quality Restoration & Roofing, Inc., failed to submit documents to OSHA verifying that each of the following cited violations had been corrected:     Citation Number                     Item Number                           Abatement Date          01                                            01                                         10/09/2018         01                                            02                                         10/09/2018         01                                            03                                         10/09/2018     In accordance with 29 CFR 1903.19(d), abatement documentation is required for this violation.
Recent events (1)
  • — Z (O) $311

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 14, 2018
Abate by
Oct 9, 2018
Penalty
Initial $3,880 · Current $3,000 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     On or about 10 September 2018, the employer failed to ensure employees were using personal fall arrest systems.  Employees were exposed to fall hazards from approximately 9 feet while not understanding the safe application of provided fall arrest/fall restraint systems.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3880

1926.502 D21

Other-than-serious 1 instance 5 exposed
Issued
Sep 14, 2018
Abate by
Oct 9, 2018
Penalty
Initial $3,880 · Current $0 Reduced
29 CFR 1926.502(d)(21): Personal fall arrest systems shall be inspected prior to each use for wear, damage and other deterioration, and defective components shall be removed from service.    On or about 10 September 2018 - employees were removing / replacing roofing material on a residential building. The employer failed to remove defective / damaged personal fall arrest systems from use. Employees were thereby exposed to fall hazards.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $0
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 14, 2018
Abate by
Oct 9, 2018
Penalty
Initial $3,880 · Current $2,000 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support:    On or about 10 September 2018, an employee engaged in a residential roofing removal/installation was provided with a metal extension ladder that was not extended at least three feet above the eave to allow for safe access to the roof. This exposed the employee to a fall of approximately 9 feet onto concrete.     Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3880

View Quality Restoration & Roofing INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343453643.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.