Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WESTERN FOUNDRIES, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of WESTERN FOUNDRIES, INC. in 100 MARTIN ST., LONGMONT, CO 80501 (NAICS 331511). OSHA activity number 343537767.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Western Foundries, INC. — free Get an email when a new federal OSHA severe-injury report for Western Foundries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 MARTIN ST.
City
LONGMONT
State
CO
ZIP
80501
Mailing
P.O. BOX 599, LONGMONT, CO 80501
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
30
Ownership type
A

4 citations on file for this inspection.

1910.1053 E01

Serious Gravity 1 1 instance 30 exposed
Issued
Dec 27, 2018
Abate by
Mar 4, 2019
Penalty
Initial $3,880 · Current $2,300 Reduced
29 CFR 1910.1053(e)(1): The employer did not establish a regulated area wherever an employee's exposure to airborne concentrations of respirable crystalline silica was, or could have been reasonably expected to be, in excess of the PEL:    (a) Western Foundries, Inc. at 100 Martin St. Longmont, CO 80501: On or before 11/02/18 the employer did not establish a regulated area in accordance with this standard where employees have been known to be over-exposed to respirable crystalline silica. Employees are exposed to crystalline silica primarily in the mold, core and grinding areas of the foundry. This condition exposed employees to respirable crystalline silica.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $3880

1910.1053 D03 IV

Serious Gravity 1 1 instance 30 exposed
Issued
Dec 27, 2018
Abate by
Mar 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1053(d)(3)(iv): Where the most recent exposure monitoring indicated that employee exposures were above the PEL, the employer did not repeat such monitoring within three months of the most recent monitoring:  (a) Western Foundries, Inc. at 100 Martin St. Longmont, CO 80501: On or before 11/02/18 the employer did not re-sample three months after employees were found to be overexposed to respirable crystalline silica. The employer had conducted air monitoring and documented at least one overexposure to respirable crystalline silica. This condition exposed employees to respirable crystalline silica.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1053 J03 I

Serious Gravity 1 1 instance 30 exposed
Issued
Dec 27, 2018
Abate by
Mar 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1053(j)(3)(i): The employer did ensure that each employee covered by this section could demonstrate knowledge and understanding of  the health hazards associated with exposure to respirable crystalline silica; specific tasks in the workplace that could result in exposure to respirable crystalline silica; specific measures the employer has implemented to protect employees from exposure to respirable crystalline silica; the contents of this section; and the purpose and a description of the medical surveillance program required by paragraph (i) of this section:  (a) Western Foundries, Inc. at 100 Martin St. Longmont, CO 80501: On or before 11/02/18 the employer did not ensure employees covered by this section demonstrated knowledge of the health hazards associated with exposure to respirable crystalline silica by training them in accordance with this section. This condition exposed employees to respirable crystalline silica.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D03 III B 2

Other-than-serious 1 instance 30 exposed
Issued
Dec 27, 2018
Abate by
Mar 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life:  (a) Western Foundries, Inc. at 100 Martin St. Longmont, CO 80501: On or before 11/02/18 the employer did not implement a cartridge change schedule for respirators not equipped with an end-of-service-life-indicator. Employees wear both tight-fitting and loose fitting respirators. This condition exposed employees to respiratory hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Western Foundries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343537767.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.