OSHA Inspection: EAST COAST ERECTORS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EAST COAST ERECTORS LLC in 7 BOYDEN LN, DEERFIELD, MA 01342 (NAICS 238120). OSHA activity number 343539268.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch East Coast Erectors LLC — free Get an email when a new federal OSHA severe-injury report for East Coast Erectors LLC is published. One employer, no account, unsubscribe in one click.
Site address
7 BOYDEN LN
City
DEERFIELD
State
MA
ZIP
01342
Mailing
161 OGDEN LORD ROAD, MARLBOROUGH, CT 06447
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.502 D06 II

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 28, 2019
Penalty
Initial $3,978 · Current $2,785 Reduced
29 CFR 1926.502(d)(6)(ii):Locking type snaphooks, not designed for the connection, were engaged to each other  a) 7 Boyden Ln. Deerfield Academy Wellness Center (being constructed), Deerfield, MA: On or about October 17, 2018 two employees were observed to have the snaphooks of their retractable lifelines attached to the snaphooks of their 6 foot webbed lanyards.   Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (2)
  • — I (S) $2784.6
  • — Z (S) $3978

1926.502 D16 III

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 28, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems were not be rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level:   a) 7 Boyden Ln. Deerfield Academy Wellness Center (being constructed), Deerfield, MA: On or about October 17, 2018 two employees were observed to have their fall arrest systems rigged so that they could fall more than 6 feet or contact a lower level.  Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View East Coast Erectors LLC's full OSHA safety record →