Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THAMES SHIPYARD & REPAIR CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THAMES SHIPYARD & REPAIR CO., INC. in 50 FARNSWORTH STREET, NEW LONDON, CT 06320 (NAICS 336611). OSHA activity number 343549036.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thames Shipyard & Repair CO., INC. — free Get an email when a new federal OSHA severe-injury report for Thames Shipyard & Repair CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
50 FARNSWORTH STREET
City
NEW LONDON
State
CT
ZIP
06320
Mailing
2 FERRY STREET, P.O. BOX 791, NEW LONDON, CT 06320
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
55
Ownership type
A

11 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 8 exposed
Issued
Dec 18, 2018
Penalty
Initial $9,054 · Current $4,527 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that adequate fall protection systems were not provided on elevating work platforms:    Small Dry Dock:  On, or about, October 19, 2018, the guardrail systems provided on the following scissor lifts were not adequate:   A.  Upright SL26, brown, unmarked lift with green paint on the under support:  Snap bolt clips were used to secure the chain provided for the platform access opening.  The snap bolt clips were not rated to withstand a load of 300 pounds and one of the snap bolts was stuck in the open position   B.  Upright SL26, SWL 1250:  A top rail was bent and creased, a midrail was significantly corroded and a corner upright was broken.
Recent events (2)
  • — I (S) $4527
  • — Z (S) $9054

1910.212 A01

Serious Gravity 5 2 instances 5 exposed
Issued
Dec 18, 2018
Abate by
Mar 8, 2019
Penalty
Initial $5,497 · Current $2,749 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   On, or about, October 23, 2018, in the following locations, machines were not provided with adequate safeguarding:  A.  Machine Shop:  The lead screw provided on the Harrison horizontal lathe was not protected against accidental contact.  B.  Plate Shop:  Point of operation safeguarding was not provided on the Chicago, Dreis and Krump fourteen foot press brake.
Recent events (2)
  • — I (S) $2748.5
  • — Z (S) $5497

1910.303 G01 I C

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 18, 2018
Penalty
Initial $2,803 · Current $1,402 Reduced
29 CFR 1910.303(g)(1)(i)(C): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized,the width of work space was not clear and did not extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of 29 CFR 1910.303.  Other equipment associated with the electrical installation and located above or below the electric equipment extended more than 153 mm(6 in.) beyond the front of the electric equipment:     Mechanic Shop:   On, or about, October 23, 2018, a GE transformer was installed in the working space in front of a 480 Square D panelboard.
Recent events (2)
  • — I (S) $1401.5
  • — Z (S) $2803

1910.303 G01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 18, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:     Red Barge:  On, or about, October 19, 2018, a pallet of tools and supplies was stored in the working space in front of Panel RB-1, a General Electric 480 volt panelboard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 10 exposed
Issued
Dec 18, 2018
Penalty
Initial $2,803 · Current $1,402 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  YTT:  On, or about, October 19, 2018, a yellow extension cord was used to energize a microwave oven.
Recent events (2)
  • — I (S) $1401.5
  • — Z (S) $2803

1910.305 J02 I

Serious Gravity 1 1 instance 10 exposed
Issued
Dec 18, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(i): Receptacles were installed so that an energized attachment plug was its source of supply:  YTT, Port Side:  On, or about, October 19, 2018, a flexible cord that was energized through an attachment plug was used to energize a receptacle mounted on a work bench.  The receptacle was used to energize a refrigerator and microwave oven.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.332 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 18, 2018
Penalty
Initial $5,497 · Current $2,749 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:   Shipyard:  On, or about, November 6, 2018, maintenance personnel had not been trained regarding what work practices and protective equipment was required to protect them against electric shock, arc flash and arc blast hazards while working on or around electrical equipment when verifying whether or not electrical equipment was properly de-energized.
Recent events (2)
  • — I (S) $2748.5
  • — Z (S) $5497

1910.334 A02 II

Serious Gravity 5 2 instances 11 exposed
Issued
Dec 18, 2018
Penalty
Initial $3,738 · Current $1,869 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:  A.  Dry Dock 1:  On, or about, October 19, 2018, a yellow extension cord used to energize a blower was damaged and wrapped with electrical tape.    B.  Near Red Barge:  On, or about, October 19, 2018, a yellow extension cord used to provide shore power to the vessel Adam was damaged and wrapped with electrical tape.  Also, the cord had been flattened from vehicles driving over the cord.
Recent events (2)
  • — I (S) $1869
  • — Z (S) $3738

1915.89 K02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 18, 2018
Penalty
Initial $5,497 · Current $2,749 Reduced
29 CFR 1915.89(k)(2)(i):   Each authorized employee did not apply a personal lockout/tags-plus system during lockout:  Shipyard:  On, or about, November 6, 2018, an employee who performed maintenance tasks to assist the Electrician was not provided with a lock and did not apply a lock to a group lockout device when working on equipment that had been de-energized and locked out by the Electrician.  Under group lockout requirements, all employees were required to be provided with equal protection under lockout conditions.
Recent events (2)
  • — I (S) $2748.5
  • — Z (S) $5497

1915.159 C05

Serious Gravity 10 2 instances 10 exposed
Issued
Dec 18, 2018
Penalty
Initial $9,054 · Current $4,527 Reduced
29 CFR 1915.159(c)(5): Defective fall arrest system components were not removed from service:     A.  Near Dry Dock 1:  On, or about, October 19, 2018, a Miller harness provided for use on the Genie Z-60/34 aerial lift was damaged in that he webbing material was cut.    B.  Small Dry Dock:  On, or about, October 19, 2018, the self-closing carabiner provided on the Miller TurboLite self-retracting lanyard was stuck in the unlocked position as it was attached to the anchor point on the Marklift Challenger aerial lift work platform.
Recent events (2)
  • — I (S) $4527
  • — Z (S) $9054

1910.169 B03 I

Other-than-serious 1 instance 4 exposed
Issued
Dec 18, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.169(b)(3)(i): Compressed air receiver(s) were not equipped with one or more spring-loaded safety valves:    Blast Tank near Small Dry Dock:  On, or about, October 19, 2018, the "deadman" air supply tank mounted on the side of the main tank was not provided with a pressure relief valve.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Thames Shipyard & Repair CO., INC.'s full OSHA safety record →