DELAWARE, OH —
OSHA Inspection: CHROMA COLOR CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHROMA COLOR CORPORATION in 100 COLOMET DRIVE, DELAWARE, OH 43015 (NAICS 325211). OSHA activity number 343749594.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHROMA COLOR CORPORATION
- Site address
- 100 COLOMET DRIVE
- City
- DELAWARE
- State
- OH
- ZIP
- 43015
- Mailing
- 100 COLOMET DRIVE, DELAWARE, OH 43015
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 30
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- May 29, 2019
- Abate by
- Jun 18, 2019
- Penalty
- Initial $8,051 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: [B] Specific procedural steps for shutting down, isolating, blocking an securing machines or equipment to control hazardous energy; [D] Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. a. On or about January 18, 2019, located on Line #2 extruder, the lockout/tagout procedures for the extruder did not include heat as a source of thermal energy, did not specifically outline the rules and techniques for shutting down the extruder (i.e. which stop button to press) and did not indicate which start button to press for verification of deenergization.
Recent events (2)
- — I (S) $0
- — Z (S) $8051
1910.147 D
- Issued
- May 29, 2019
- Abate by
- Jun 18, 2019
- Penalty
- Initial $8,051 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: a. On or about January 18, 2019, located on Line #2 extruder, employees were exposed to caught-in hazards when employees cleaned out the throat on the Line #2 extruder. The employer did implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implanted to protect employees from machine servicing hazards. On January 18, 2019, lockout/tagout was not performed prior to cleaning the throat on the Line #2 extruder with the use of a rag. The cleaning rag and employees hand was pulled into the extruders rotating screw causing an amputation and avulsion to the employees fingers.
Recent events (2)
- — I (S) $0
- — Z (S) $8051
1910.333 A
- Issued
- May 29, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $13,260 · Current $11,270 Reduced
General-duty citation text
29 CFR 1910.333(a): "General." Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized. The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards. a. On or about January 22, 2019, located on Line 5 panel, safety-related work practices were not used when employees worked in an electrical panel when changing out a heater, thereby exposing employees to a 480 vac electrical shock and/or arc flash incident.
Recent events (2)
- — I (S) $11270
- — Z (S) $13260
1910.335 A01 I
- Issued
- May 29, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed. a. On or about January 22, 2019, located on Line 5 panel, employees were not provided with and did not use electrical protective equipment when working in an electrical panel when changing out a heater, thereby exposing employees to a 480 VAC electrical shock and/or arc flash incident.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Chroma Color Corporation
View Chroma Color Corporation's full OSHA safety record →
More inspections in this industry (NAICS 325211)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343749594.